2.1 Function Code Tables
2-11
Chap. 2
FUNCTION C
O
DES
Code
Name
Data setting range
Incr
em
ent
Un
it
Ch
a
n
ge
wh
en
runni
n
g
Da
ta
cop
yin
g
Default s
e
ttin
g
Data f
o
rm
a
t No.
To
rq
ue v
e
ctor
contr
o
l
Softw
ar
e ver
si
o
n
wh
ich
ca
n b
e
used
H64 Zero Speed Holding Time
0.00 to 10.00
0.01
s
N
Y
0.00
5
N
H65
Starting Speed
(Soft start time)
0.0 to 60.0
0.1
s
N
Y
0.0
3
Y
H66
Stop Speed
(Detection method)
0: Use detected speed
-
-
N
Y
0
1
Y
1: Use reference speed (final)
H67
(Holding time)
0.00 to 10.00
0.01
s
N
Y
1.00
5
Y
H72
Main power shutdown detection
(Mode
selection)
0:Invalid
1:Valid
H74
Speed
Agreement
(Hysteresis)
0.00 to 6000 *1
(Equivalent with 0.00 to 200.00 Hz)
Variable
*3
Y
Y
10.00
37
N
H75
(OFF delay time)
0.00
to
1.00
0.01
s
Y
Y
0.20
5
N
H76
PG Error Detection for Mode 3
(Detection level)
0 to 50
-
-
Y
Y
0000
H
1
Y
H77
(Detection time)
0.0 to 10.0
-
-
Y
Y
0000
H
1
Y
H80 Exciting current damping gain
0.00 to 1.00
0.01
-
Y
Y
0.20
5
Y
*8
H81
Auto Reset
(Mode selection 1)
0000
H
to FFFF
H
-
-
Y
Y
0000
H
1
Y
H82
(Mode selection 2)
0000
H
to FFFF
H
-
-
Y
Y
0000
H
1
Y
H89
Strore electronic thremal overload
0: Clears cumulative value of thermal by inverter power-off.
1
-
Y
Y
0
1
Y
500
protection data for motor
1: Retains cumulative value of thermal
after inverter power-off.
H94
Cumulative Run Time of Motor
0 to 9999: Cumulative run time can be modified or reset in units
of 10 hours
-
-
N
N
0
74
Y
H95
Clear bbE Alarm
0 to 255
1
-
N
N
0
1
Y
H96
Check brake control select
0: BRKE is active
-
-
N
Y
0
1
Y
1: BRKE1 and BRKE2 are active
H97
Clear Alarm Data
If H97= 1, its data returns to zero after clearing alarm data.
-
-
Y
N
0
1
Y
H98
Protection/Maintenance Function
00000000b
to
11111111b (0 to 255)
-
-
Y
Y
01010001
1
-
(81)
Bit 0: Lower the carrier frequency automatically
Y
Bit 1: Detect input phase loss
Y
Bit 2: etect output phase loss
Y
Bit 3: Select life judgment criteria of DC link bus capacitor
Y
Bit 4: Judge the life of DC link bus capacitor
Y
Bit
5
Reserved
Y
Bit 6: Detect DB-Tr broken
Y
Bit 7: Detect thermistor disconnect for heat sink
Y
H99
Password Protection
0000H to FFFFH
-
-
Y
N
0000
H
1
Y
0000
H
: Disable password protection
0001
H
to FFFF
H
: Enable password protection
H190 Terminal [UVW] Output order
0: Normal (FWD = UVW)
-
-
N
Y
1
1
Y
1:
Inverse
(FWD
=
UWV)
*3 The unit changes depending on the setting of C21.
*8 This function code is only for the torque vector control.