2.1 Function Code Tables
2-7
Chap. 2
FUNCTION C
O
DES
Code
Name
Data setting range
Incr
em
ent
Un
it
Ch
a
n
ge
wh
en
runni
n
g
Da
ta
cop
yin
g
Default s
e
ttin
g
Data f
o
rm
a
t No.
To
rq
ue v
e
ctor
contr
o
l
Softw
ar
e ver
si
o
n
wh
ich
ca
n b
e
used
E30 Speed
Arrival
(FAR)
(Hysteresis)
0.00 to 6000
*1
(Equivalent with 0.00 to 200.00 Hz)
Variable
*3
Y
Y
14.5
*2
37
Y
E31 Speed Detection (FDT)
(Detection
level)
0.00 to 6000
*1
(Equivalent with 0.00 to 200.00 Hz)
Variable
*3
Y
Y
1450
*2
37
Y
E32
(Hysteresis)
0.00 to 900.0
*1
(Equivalent with 0.00 to 30.00 Hz)
Variable
*3
Y
Y
14.5
*2
37
Y
E34 Current Detection 1 (ID)
When you set 1 to L98:bit0,
Refer to
E34 and E35 are effective over torque current alarm (0t).
default
(Level
1)
0.00: (Disable)
Variable
A
Y
Y1 Y2
table
24
Y
Current value of 1 to 200% of the inverter rated current
E35
(Time)
0.01
to
600.00
E36
Speed Detection 2 (FDT2)
(Detection level)
0.00
to
6000
*1
(Equivalent with 0.00 to 200.00 Hz)
Variable
*3
Y
Y
1450
*2
37
Y
E37
Current Detection 2 (ID2)
Refer
to
(Level
2)
0.00: (Disable)
Variable
A
Y
Y1 Y2
default
24
Y
Current value of 1 to 200% of the inverter rated current
table
E39
Recommended running
direction (RRD)
(Detection level)
0 to 100
1
%
N
Y
0
1
N
E43
LED Monitor
-
-
Y
Y
0
1
-
0: Speed monitor (Select by E48)
-
3:
Output
current
Y
4:
Output
voltage
Y
8:
Calculated
torque
Y
9:
Input
power
Y
18:
Reference
torque
N
19: Torque bias balance adjustment (Offset) (BTBB)
N
20: Torque bias gain adjustment (BTBG)
N
E45
Reserved
*4
-
-
-
Y
Y
0
1
Y
E46
Reserved
*4
-
-
-
Y
Y
1
1
Y
E47
Reserved
*4
-
-
-
Y
Y
5
1
Y
E48 LED
Monitor
-
-
Y
Y
0
1
-
(Speed monitor item)
0: Reference speed (final)
Y
2:
Reference
speed
(pre-ramp)
Y
3:
Motor
speed
Y
*5
5:
Elevator
speed
Y
*5
8:
Elevator
speed
(mm/s)
Y
*5
E52
Keypad(Menu display mode)
0: Function code data editing mode
1
-
N
Y
0
1
Y
1: Function code data check mode
2:
Full-menu
mode
E59 Terminal
[C1]
Type
selection
0:
Current input: 0 to 20 mA (C1 function)
1
-
Y
Y
1
1
Y
(C1/V2)
1: Voltage input: 0 to 10 V (V2 function)
E61 Analog Input for:
Selecting function code data assigns the corresponding
(Extension
function
selection)
function to terminals [12], [C1] and [V2] as listed below.
[12]
-
-
N
Y
0
1
-
E62
[C1]
-
-
N
Y
0
1
-
E63
[V2]
-
-
N
Y
0
1
-
0:
None
Y
1: Speed command
(Not reversible operation with polarity)
Y
2: Speed command
(Reversible operation with polarity) (Nothing for [C1])
Y
4: Torque bias command
N
E98 Command
Assignment
to:
Selecting function code data assigns the corresponding
[FWD]
function to terminals [FWD] and [REV] as same as E01.
-
-
N
Y
98
1
-
E99
Additional available settings against E01 are listed below.
-
-
N
Y
99
1
-
98: FWD Run
forward
Y
99: REV Run reverse
Y
*1 The data setting range is variable. Refer to Section 2.2.
*2 The factory default setting varies depending on the shipping destination.
*3 The unit changes depending on the setting of C21.
*4 Reserved for particular manufacturers. Do not access this function code.
*5 It is indicated depending on reference speed (final).