H57 to H60
S-curve Setting 10 to 14
F01 (Speed Command)
L19 to L28 specify S-curve zones to be applied to operations driven by multistep speed commands
with S-curve acceleration/deceleration.
The setting values are indicated in percentage to the maximum speed.
- Data setting range: 0 to 50 (%)
Refer to the description of function code F01 for details.
H64
Zero speed control time
F23, F24 (Starting Speed)
H64 sets the time duration of zero speed control (or DC braking) from the moment that inverter is
turned ON.
- Data setting range: 0.00 to 10.00 (s)
For details, refer to function code F23, F24.
H65
Starting Speed (Soft start time)
F23 (Starting Speed)
H65 specifies the acceleration time until the speed reaches the starting speed. The specified time is
the one required for accelerating from 0.00 to the starting speed (r/min).
- Data setting range: 0.0 to 60.0 (s)
For details, refer to function code F23.
H66
Stop Speed (Detection method)
F25 (Stop Speed)
H66 specifies the stop speed detection method.
Data for H66
Detection method
0
Use the detected speed.*
1
Use the reference speed (final).
For details, refer to the description of function code F25.
*In case of Torque Vector Control inverter uses Reference Speed (Final)
H67
Stop Speed (Holding time)
F25 (Stop Speed)
H67 specifies the run command holding time as soon as stop speed is reached.
- Data setting range: 0.00 to 10.00 (s)
For details, refer to function code F25.