U00
U01 to U70
U71 to U80
U81 to U90
U91
U100
U121 to U140
U171 to U175
U190 to U195
Customizable logic (Mode selection)
Customizable logic: Step 1 to 14 (Mode setting)
Customizable logic: Output signal 1 to 10 (Output selection)
Customizable logic: Output signal 1 to 10 (Function selection)
Customizable logic: Timer monitor (Step selection)
Customizable logic: Task process cycle setting
Customizable logic: User parameter 1 to 20
Customizable logic: Storage area 1 to 5
Customizable logic: Step 15 to 200 setting
■
Customizable Logic (Mode selection) (U00)
U00 specifies whether to enable the sequence configured with the customizable logic function or
disable it to run the inverter only via its input terminals or others.
U00 data
Function
0
Disable
1
Enable (Customizable logic operation)
The
ECL
alarm occurs when changing U00 from 1 to 0 during operation.
■
Customizable Logic (Mode Setting) (U01 to U70, U190 to U195)
In the customizable logic, the steps are categorized in the following three types:
[Input: digital] Block selection (U01, U06, U11, etc.) = 1 to 1999
Input 1 (digital)
Input 2 (digital)
Output (digital)
Time
setting
Logic circuit
General-
purpose timer
[Input: analog] Block selection (U01, U06, U11, etc.) = 2001 to 3999
Input 1 (analog)
Input 2 (analog)
Output (analog/digital)
Operation
circuit
[Input: digital, analog] Block selection (U01, U06, U11, etc.) = 4001 to 5999
Input 1 (analog)
Input 2 (digital)
Output (analog)
Operation
circuit
Logic circuit
2-110