When special alarm happens, the inverter keeps driving the motor for ten seconds by drive
continuance alarm. After 10 seconds, if the output is shut down, drive continuance alarm will happen
and inverter will stop. Drive continuance alarm will be kept until inverter is reset.
Drive continuance object alarm occurrence
Drive continuance excluded alarm occurence
Both type of alarms occurrence
Alarm occur
ON
ON
Driving
Drive
Drive continuance
stop
Inverter driving
Driving signal
[RUN]
Drive
continuance
alarm
[ALM2]
Alarm
output[ALM]
Object alarm
10s
Alarm occur
ON
ON
Driving
Driving
Stop
Inverter
operation
Drinving signal
[RUN]
Drive
continuance
alarm output
[ALM2]
Alarm output
[ALM]
Excluding alarm
Alarm occur
ON
ON
Driving
Driving
Drive
continuanc
Stop
Inverter
operation
Driving signal
[RUN]
Drive
continuance
alarm
[ALM2]
Alarm output
[ALM]
Object alarm
Less than 10
seconds
Alarm occur
Excluding alarm
2-174