L108
Encoder Rotation (Detection speed)
L108 specifies the speed detection threshold for rotation direction indication from the speed
measured by the encoder.
- Data setting range: 0.00 to 500.0 mm/s
Refer to the explanation of “
FRUN
” and “
RRUN
”.
L109
Travel direction counter (Password setting)
L110
Travel direction counter (Password unlock)
L111
Travel direction counter (Travel limit)
L112
Travel direction counter (Warning level)
L113
Travel direction counter (Partial number of direction changes)
L114
Travel direction counter (Total number of direction changes)
L115
Travel direction counter (Total number of resets)
Travel direction counter function (TDC) provides the information for the maintenance of suspension
means (coated ropes or belts).
This function is available only in combination with Multi-function keypad TP-A1-LM2 (option).
■
Travel direction counter (Password setting) (L109)
In this function code a password for TDC must be set. In other words, until password is not defined
in L109, TDC function remains disabled.
Data for L109
Action
0000h
No password.
Function disabled.
0001h~FFFFh Password setting range.
As soon as password is defined, L109 returns to default setting value (0000h).
After defining a password TDC function has to be locked. To do so, please turn the power
supply of the inverter OFF, wait until keypad is unlit and switch ON again.
■
Travel direction counter (Password unlock) (L110)
After TDC function has been enabled by setting a password in L109, password can be set on this
function code to unlock menus 2. Setting, 4. Set PW and 5. TDC Copy.
Data for L111
Action
0000h
No password.
Function locked.
0001h~FFFFh Password setting range.
As soon as password is defined, L110 returns to default setting value (0000h).
After modify TDC function parameters, make sure function is locked again. To do so,
please turn the power supply of the inverter OFF, wait until keypad is unlit and switch ON
again.
■
Travel direction counter (Travel limit) (L111)
Maximum travel direction changes allowed are set in this function code. When counter L113 reaches
this level, in other words when L111=L113, inverter will be blocked by
tCA
.
2-182