L codes (Lift functions)
2.3.8
L01
Pulse Encoder (Selection)
L01 specifies the specifications of a pulse encoder system to be used for speed detection.
Data for L01
Applicable encoder specifications
Required option
Applicable
motor
A/B phase output
Absolute signal spec.
0
12/15V complementary
12,15V open collector
None
OPC-G1-PG
OPC-PG3
Asynchronous
motor
5V line driver
None
OPC-G1-PG2
OPC-PMPG
1
12/15V complementary
Z
OPC-G1-PG
OPC-PG3
Synchronous
motor
5V line driver
Z
OPC-G1-PG2
OPC-PMPG
4
Sinusoidal differential
voltage 1 Vp-p
EnDat2.1
(HEIDENHAIN
ECN1313 or its
equivalent)
OPC-PS
or
OPC-PSH
Synchronous
motor
5
Sinusoidal differential
voltage 1 Vp-p
SIN/COS
(HEIDENHAIN
ERN1387 or its
equivalent)
OPC-PR
Synchronous
motor
6
Sinusoidal differential
voltage 1 Vp-p
BiSS-C
(Kubler Sendix5873
or its equivalent)
OPC-PS
or
OPC-PSH
Synchronous
motor
7
Sinusoidal differential
voltage 1 Vp-p
SSI
(HEIDENHAIN
ECN1313 or its
equivalent)
OPC-PS
or
OPC-PSH
Synchronous
motor
8
Sinusoidal differential
voltage 1 Vp-p
Hiperface
(SICK SRS50 or its
equivalent)
OPC-PSH
Synchronous
motor
L02
Pulse Encoder (Resolution)
L02 specifies the resolution of the pulse encoder to be used for speed detection.
Improper setting of the resolution causes an incorrect detection of the speed and magnet pole
position, making accurate speed control and vector control impossible.
- Data setting range: 360 to 60000 (P/R)
2-140