Safety Information
Extreme Networks Consolidated ExtremeXOS Hardware Installation Guide
372
Installing Power Supply Units
For the ratings and power requirements of each power supply unit, see
Appendix B, “Technical
Specifications”
or the data sheet for the power supply at
http://www.extremenetworks.com
.
WARNING!
Be sure that the following requirements are satisfied when installing all Extreme Networks power supplies.
Make sure to satisfy the following requirements:
●
Plug power supplies only into properly grounded electrical outlets to help prevent electrical shock
and comply with international safety standards.
●
Use only power cords that are certified for use within the country of use. Do not attempt to modify
AC power cords.
●
The wall outlet must be installed near the equipment and be easily accessible for quick disconnect.
●
Make sure the voltage and frequency of your power outlet match the equipment’s system’s electrical
ratings. The building and/or power source must provide overload protection.
●
Use a surge suppressor, line conditioner, or uninterruptible power supply to protect the system from
momentary increases or decreases in electrical power.
●
For hot-swappable power supplies, do not slam the PSU into the bay.
●
If multiple power supplies are used in a switch, connect each power supply to a different,
independent power source. If a single power source fails, it will affect only that power supply to
which it is connected. If all the power supplies on a single switch are connected to the same power
source, the entire switch is vulnerable to a power failure.
WARNING!
Extreme Networks 325 W DC PSUs do not have switches for turning the unit on and off. Make sure that the DC
circuit is de-energized before connecting or disconnecting the DC power cord at the DC power socket on the Extreme
Networks 325 W DC PSU.
Wiring the 325 W DC PSU DC power cord to your facility DC source voltage must be performed by a qualified,
licensed electrician.
Extreme Networks 325 W AC PSUs do not have switches for turning the unit on and off. Remove the wall plug from
the electrical outlet to disconnect the power to an Extreme Networks 325 W AC PSU. Make sure that this
connection is easily accessible.
Do not connect the power supply into an electrical outlet when the power supply is outside the chassis; doing so
would expose a hazardous energy and poses a potential shock and fire hazard.
Do not put your hand into an open power supply bay when a power supply is not present. Empty power supply bays
require a cover plate at all times.
Summary of Contents for BlackDiamond 10808
Page 14: ...Table of Contents Extreme Networks Consolidated ExtremeXOS Hardware Installation Guide 14 ...
Page 18: ...Preface Extreme Networks Consolidated ExtremeXOS Hardware Installation Guide 18 ...
Page 19: ...1 Site Preparation ...
Page 20: ......
Page 40: ...Site Preparation Extreme Networks Consolidated ExtremeXOS Hardware Installation Guide 40 ...
Page 41: ...2 BlackDiamond Switches ...
Page 42: ......
Page 93: ...3 Installing BlackDiamond Switches and Modules ...
Page 94: ......
Page 189: ...4 Installing BlackDiamond Switch Accessories ...
Page 190: ......
Page 207: ...5 BlackDiamond Maintenance Procedures ...
Page 208: ......
Page 239: ...6 Summit Family of Switches ...
Page 240: ......
Page 335: ...7 Optics ...
Page 336: ......
Page 363: ...8 Initial Management Access ...
Page 364: ......
Page 369: ...9 Appendixes ...
Page 370: ......