![Ericsson ECN330 User Manual Download Page 791](http://html1.mh-extra.com/html/ericsson/ecn330/ecn330_user-manual_2423382791.webp)
Command Line Interface
785
1553-KDU 137 365 Uen D 2006-06-16
7.13.6
show power mainpower
Use this command to display the current power status for the ECN330.
Command Mode
Privileged Exec
Example
Table 83 show power mainpower - Display Description
Console#show power mainpower
Unit 1 Mainpower Status
Maximum Available Power : 555 watts
System Operation Status : on
Mainpower Consumption : 15 watts
Thermal Temperature : 41 (in Celsius)
Software Version : Version 0x1B6F, Build 0x07
Console#
Field
Description
Maximum
Available
Power
The available power budget for the ECN330
(configurable, see section 7.13.1 on page 779).
System
Operation
Status
The current operating power status for the ECN330
(displays
on
or
off
).
Mainpower
Consumption
The current power consumption on the ECN330 in watts.
Thermal
Temperature
The current internal temperature of the ECN330. Note
that the ECN330 automatically shuts down if the
measured temperature exceeds 80 degrees Celsius.
Summary of Contents for ECN330
Page 6: ...1553 KDU 137 365 Uen D 2006 06 16 Contents List of Abbreviations 1183 Glossary 1191 Index 1201...
Page 22: ...Introduction to the ECN330 switch 16 1553 KDU 137 365 Uen D 2006 06 16...
Page 26: ...Maintenance 20 1553 KDU 137 365 Uen D 2006 06 16...
Page 56: ...Initial Configuration 50 1553 KDU 137 365 Uen D 2006 06 16...
Page 520: ...Configuring the ECN330 switch 514 1553 KDU 137 365 Uen D 2006 06 16...
Page 1188: ...Specifications 1182 1553 KDU 137 365 Uen D 2006 06 16...
Page 1196: ...List of Abbreviations 1190 1553 KDU 137 365 Uen D 2006 06 16...
Page 1224: ...Index 1218 1553 KDU 137 365 Uen D 2006 06 16...
Page 1225: ......