![Ericsson ECN330 User Manual Download Page 1116](http://html1.mh-extra.com/html/ericsson/ecn330/ecn330_user-manual_24233821116.webp)
Command Line Interface
1110
1553-KDU 137 365 Uen D 2006-06-16
7.27.4
probe-interval
This command sets the interval for sending neighbor probe messages to the
multicast group address for all DVMRP routers. Use the
no
form to restore the
default value.
Syntax
probe-interval <
seconds
>
no probe-interval
seconds
- Interval between sending neighbor probe messages.
(Range: 1-65535)
Default Setting
10 seconds
Command Mode
Router Configuration
Command Usage
Probe messages are sent to neighboring DVMRP routers from which this
device has received probes, and is used to verify whether or not these
neighbors are still active members of the multicast tree.
Example
Console(config-router)#probe-interval 30
Console(config-router)#