Operating variable
Unit
hex
Parameter 16-01 Reference [Unit]
[Unit]
%
hex
Parameter 16-05 Main Actual Value [%]
%
Parameter 16-09 Custom Readout
Parameter 16-10 Power [kW]
[kW]
[hp]
[V]
[Hz]
[A]
Parameter 16-15 Frequency [%]
Parameter 16-16 Torque [Nm]
Nm
[RPM]
%
Parameter 16-20 Motor Angle
Parameter 16-21 Torque [%] High Res.
Parameter 16-22 Torque [%]
Parameter 16-24 Calibrated Stator Resistance
Parameter 16-30 DC Link Voltage
V
Parameter 16-34 Heatsink Temp.
°
C
Parameter 16-35 Inverter Thermal
%
Parameter 16-36 Inv. Nom. Current
A
Parameter 16-37 Inv. Max. Current
A
Parameter 16-38 SL Controller State
Parameter 16-39 Control Card Temp.
°
C
Parameter 16-40 Logging Buffer Full
Parameter 16-45 Motor Phase U Current
Parameter 16-46 Motor Phase V Current
Parameter 16-47 Motor Phase W Current
Parameter 16-48 Speed Ref. After Ramp [RPM]
Parameter 16-49 Current Fault Source
Parameter 16-50 External Reference
Parameter 16-51 Pulse Reference
Parameter 16-52 Feedback[Unit]
[Unit]
Parameter 16-53 Digi Pot Reference
Parameter 16-57 Feedback [RPM]
Parameter 16-60 Digital Input
bin
Parameter 16-61 Terminal 53 Switch Setting
V
Parameter 16-62 Analog Input 53
Parameter 16-63 Terminal 54 Switch Setting
V
Parameter 16-64 Analog Input 54
Parameter 16-65 Analog Output 42 [mA]
[mA]
Parameter 16-66 Digital Output [bin]
[bin]
Parameter 16-67 Pulse Input #29 [Hz]
[Hz]
Parameter 16-68 Freq. Input #33 [Hz]
[Hz]
Parameter 16-69 Pulse Output #27 [Hz]
[Hz]
Parameter 16-70 Pulse Output #29 [Hz]
[Hz]
Parameter 16-71 Relay Output [bin]
Parameter 16-72 Counter A
Parameter 16-73 Counter B
Parameter 16-75 Analog In X30/11
Operating variable
Unit
Parameter 16-76 Analog In X30/12
Parameter 16-77 Analog Out X30/8 [mA]
Parameter 16-80 Fieldbus CTW 1
hex
Parameter 16-82 Fieldbus REF 1
hex
Parameter 16-84 Comm. Option STW
hex
Parameter 16-85 FC Port CTW 1
hex
Parameter 16-86 FC Port REF 1
hex
Parameter 16-87 Bus Readout Alarm/Warning
Parameter 16-90 Alarm Word
Parameter 16-91 Alarm Word 2
Parameter 16-92 Warning Word
Parameter 16-93 Warning Word 2
Parameter 16-94 Ext. Status Word
Parameter 16-95 Ext. Status Word 2
Parameter 16-97 Alarm Word 3
Parameter 16-98 Warning Word 3
Table 3.1 Units
Status view I
This readout state is standard after start-up or initialization.
Press [Info] to obtain information about the units linked to
the shown operating variables (1.1, 1.2, 1.3, 2 and 3).
See the operating variables shown in
.
1.1
2
3
1.3
1.2
130BP041.10
799 RPM
Auto Remote Ramping
1 (1)
36.4 kw
7.83 A
0.000
53.2 %
Status
Illustration 3.10 Status View I
Status view II
See the operating variables (1.1, 1.2, 1.3, and 2) shown in
In the example, speed, motor current, motor power, and
frequency are selected as variables in the 1
st
and 2
nd
lines.
1.1
1.2
2
1.3
130BP062.10
207RPM
Auto Remote Running
1 (1)
24.4 kW
5.25A
6.9
Hz
Status
Illustration 3.11 Status View II
Programming
VLT® AutomationDrive FC 361
16
Danfoss A/S © 03/2019 All rights reserved.
MG06J202
3
3