Input polarity of control terminals
12
13
18
19
27
29
32
33
20
+24
VDC
0
VDC
PNP (S our c e)
Dig ital input wir ing
e30bg750.10
Illustration 1.3 PNP (Source)
NPN (Sink)
Dig ital input wir ing
12
13
18
19
27
29
32
33
20
+24
VDC
0
VDC
e30bg751.10
Illustration 1.4 NPN (Sink)
NOTICE
Control cables must be shielded/armored.
See the section
Grounding of Shielded Control Cables
in the
design guide
for the correct termination of control cables.
130BA681.10
Illustration 1.5 Grounding of Shielded/Armored Control Cables
1.3.1 Start/Stop
Terminal 18 =
Parameter 5-10 Terminal 18 Digital Input
[8]
Start
.
Terminal 27 =
Parameter 5-12 Terminal 27 Digital Input
[0]
No operation
(Default
[2] Coast inverse
).
12 13 18
32
27
19
29
33 20
P 5-12 [0]
P 5-10 [8]
S tar t/S t op
+24V
Speed
S tar t/S t op
[18]
e30bg752.10
Illustration 1.6 Start/Stop
Introduction
VLT® AutomationDrive FC 361
8
Danfoss A/S © 03/2019 All rights reserved.
MG06J202
1
1