5.2.8 7-** Controllers
Param
eter
numb
er
Parameter description
Default value
4 set-up
Change
during
operation
Conversion
index
Type
7-0* Speed PID Ctrl.
7-00
Speed PID Feedback Source
[1] 24V encoder
All set-ups
FALSE
–
Uint8
7-02
Speed PID Proportional Gain
ExpressionLimit
All set-ups
TRUE
-3
Uint16
7-03
Speed PID Integral Time
ExpressionLimit
All set-ups
TRUE
-4
Uint32
7-04
Speed PID Differentiation Time
ExpressionLimit
All set-ups
TRUE
-4
Uint16
7-05
Speed PID Diff. Gain Limit
5 N/A
All set-ups
TRUE
-1
Uint16
7-06
Speed PID Lowpass Filter Time
ExpressionLimit
All set-ups
TRUE
-4
Uint16
7-07
Speed PID Feedback Gear Ratio
1 N/A
All set-ups
FALSE
-4
Uint32
7-08
Speed PID Feed Forward Factor
0 %
All set-ups
FALSE
0
Uint16
7-1* Torque PI Ctrl.
7-12
Torque PI Proportional Gain
100 %
All set-ups
TRUE
0
Uint16
7-13
Torque PI Integration Time
0.020 s
All set-ups
TRUE
-3
Uint16
7-2* Process Ctrl. Feedb
7-20
Process CL Feedback 1 Resource
[0] No function
All set-ups
TRUE
–
Uint8
7-22
Process CL Feedback 2 Resource
[0] No function
All set-ups
TRUE
–
Uint8
7-3* Process PID Ctrl.
7-30
Process PID Normal/ Inverse Control
[0] Normal
All set-ups
TRUE
–
Uint8
7-31
Process PID Anti Windup
[1] On
All set-ups
TRUE
–
Uint8
7-32
Process PID Start Speed
0 RPM
All set-ups
TRUE
67
Uint16
7-33
Process PID Proportional Gain
0.01 N/A
All set-ups
TRUE
-2
Uint16
7-34
Process PID Integral Time
10000 s
All set-ups
TRUE
-2
Uint32
7-35
Process PID Differentiation Time
0 s
All set-ups
TRUE
-2
Uint16
7-36
Process PID Diff. Gain Limit
5 N/A
All set-ups
TRUE
-1
Uint16
7-38
Process PID Feed Forward Factor
0 %
All set-ups
TRUE
0
Uint16
7-39
On Reference Bandwidth
5 %
All set-ups
TRUE
0
Uint8
7-4* Adv. Process PID I
7-40
Process PID I-part Reset
[0] No
All set-ups
TRUE
–
Uint8
7-41
Process PID Output Neg. Clamp
-100 %
All set-ups
TRUE
0
Int16
7-42
Process PID Output Pos. Clamp
100 %
All set-ups
TRUE
0
Int16
7-43
Process PID Gain Scale at Min. Ref.
100 %
All set-ups
TRUE
0
Int16
7-44
Process PID Gain Scale at Max. Ref.
100 %
All set-ups
TRUE
0
Int16
7-45
Process PID Feed Fwd Resource
[0] No function
All set-ups
TRUE
–
Uint8
7-46
Process PID Feed Fwd Normal/ Inv. Ctrl.
[0] Normal
All set-ups
TRUE
–
Uint8
7-48
PCD Feed Forward
0 N/A
All set-ups
TRUE
0
Uint16
7-49
Process PID Output Normal/ Inv. Ctrl.
[0] Normal
All set-ups
TRUE
–
Uint8
7-5* Adv. Process PID II
7-50
Process PID Extended PID
[1] Enabled
All set-ups
TRUE
–
Uint8
7-51
Process PID Feed Fwd Gain
1 N/A
All set-ups
TRUE
-2
Uint16
7-52
Process PID Feed Fwd Ramp up
0.01 s
All set-ups
TRUE
-2
Uint32
7-53
Process PID Feed Fwd Ramp down
0.01 s
All set-ups
TRUE
-2
Uint32
7-56
Process PID Ref. Filter Time
0.001 s
All set-ups
TRUE
-3
Uint16
7-57
Process PID Fb. Filter Time
0.001 s
All set-ups
TRUE
-3
Uint16
7-6* Feedback Conversion
7-60
Feedback 1 Conversion
[0] Linear
All set-ups
TRUE
–
Uint8
7-62
Feedback 2 Conversion
[0] Linear
All set-ups
TRUE
–
Uint8
Parameter Lists
Programming Guide
MG06J202
Danfoss A/S © 03/2019 All rights reserved.
167
5
5