15-10 Logging Source
Option:
Function:
[1647]
Motor Phase
W Current
[1648]
Speed Ref.
After Ramp
[RPM]
[1650]
External
Reference
[1651]
Pulse
Reference
[1652]
Feedback[Unit]
[1657]
Feedback
[RPM]
[1660]
Digital Input
[1662]
Analog Input
53
[1664]
Analog Input
54
[1665]
Analog Output
42 [mA]
[1666]
Digital Output
[bin]
[1675]
Analog In
X30/11
[1676]
Analog In
X30/12
[1677]
Analog Out
X30/8 [mA]
[1687]
Bus Readout
Alarm/Warning
[1690]
Alarm Word
[1692]
Warning Word
[1694]
Ext. Status
Word
[1695]
Ext. Status
Word 2
[1697]
Alarm Word 3
[1698]
Warning Word
3
15-11 Logging Interval
Array [4]
Range:
Function:
Size
related
*
[ 0.000 -
0.000 ]
Enter the interval in ms between
each sampling of the variables to
be logged.
15-12 Trigger Event
Select the trigger event. When the trigger event occurs, a
window is applied to freeze the log. The log then retains a
specified percentage of samples before the occurrence of the
trigger event (
parameter 15-14 Samples Before Trigger
).
Option:
Function:
[0]
*
False
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current Limit
[7]
Out of current
range
[8]
Below I low
[9]
Above I high
[10]
Out of speed
range
[11]
Below speed
low
[12]
Above speed
high
[13]
Out of feedb.
range
[14]
Below feedb.
low
[15]
Above feedb.
high
[16]
Thermal
warning
[17]
Mains out of
range
[18]
Reversing
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip
lock)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
[33]
Digital input
DI18
[34]
Digital input
DI19
[35]
Digital input
DI27
[36]
Digital input
DI29
Parameter Descriptions
VLT® AutomationDrive FC 361
140
Danfoss A/S © 03/2019 All rights reserved.
MG06J202
4
4
Summary of Contents for VLT AutomationDrive FC 361
Page 2: ......