5.2.13 14-** Special Functions
Param
eter
numb
er
Parameter description
Default value
4 set-up
Change
during
operation
Conversion
index
Type
14-0* Inverter Switching
14-00 Switching Pattern
[1] SFAVM
All set-ups
TRUE
–
Uint8
14-01 Switching Frequency
ExpressionLimit
All set-ups
TRUE
–
Uint8
14-03 Overmodulation
ExpressionLimit
All set-ups
FALSE
–
Uint8
14-04 Acoustic Noise Reduction
[0] Off
All set-ups
TRUE
–
Uint8
14-06 Dead Time Compensation
[1] On
All set-ups
TRUE
–
Uint8
14-1* Mains Failure
14-10 Mains Failure
[0] No function
All set-ups
TRUE
–
Uint8
14-11 Mains Fault Voltage Level
ExpressionLimit
All set-ups
TRUE
0
Uint16
14-12 Response to Mains Imbalance
[0] Trip
All set-ups
TRUE
–
Uint8
14-14 Kin. Back-up Time-out
60 s
All set-ups
TRUE
0
Uint8
14-15 Kin. Back-up Trip Recovery Level
ExpressionLimit
All set-ups
TRUE
-3
Uint32
14-16 Kin. Back-up Gain
100 %
All set-ups
TRUE
0
Uint32
14-2* Trip Reset
14-20 Reset Mode
[0] Manual reset
All set-ups
TRUE
–
Uint8
14-21 Automatic Restart Time
ExpressionLimit
All set-ups
TRUE
0
Uint16
14-22 Operation Mode
[0] Normal operation
All set-ups
TRUE
–
Uint8
14-24 Trip Delay at Current Limit
60 s
All set-ups
TRUE
0
Uint8
14-25 Trip Delay at Torque Limit
60 s
All set-ups
TRUE
0
Uint8
14-26 Trip Delay at Inverter Fault
ExpressionLimit
All set-ups
TRUE
0
Uint8
14-3* Current Limit Ctrl.
14-30 Current Lim Ctrl, Proportional Gain
100 %
All set-ups
FALSE
0
Uint16
14-31 Current Lim Ctrl, Integration Time
ExpressionLimit
All set-ups
FALSE
-3
Uint16
14-32 Current Lim Ctrl, Filter Time
ExpressionLimit
All set-ups
TRUE
-1
Uint16
14-4* Energy Optimising
14-40 VT Level
66 %
All set-ups
FALSE
0
Uint8
14-41 AEO Minimum Magnetisation
ExpressionLimit
All set-ups
TRUE
0
Uint8
14-42 Minimum AEO Frequency
ExpressionLimit
All set-ups
TRUE
0
Uint8
14-43 Motor Cosphi
ExpressionLimit
All set-ups
TRUE
-2
Uint16
14-5* Environment
14-50 RFI Filter
[1] On
1 set-up
FALSE
–
Uint8
14-51 DC-Link Compensation
ExpressionLimit
All set-ups
TRUE
–
Uint8
14-52 Fan Control
[0] Auto
All set-ups
TRUE
–
Uint8
14-53 Fan Monitor
[1] Warning
All set-ups
TRUE
–
Uint8
14-55 Output Filter
[0] No Filter
All set-ups
FALSE
–
Uint8
14-59 Actual Number of Inverter Units
ExpressionLimit
1 set-up
FALSE
0
Uint8
14-6* Auto Derate
14-60 Function at Over Temperature
[0] Trip
All set-ups
TRUE
–
Uint8
14-61 Function at Inverter Overload
[0] Trip
All set-ups
TRUE
–
Uint8
14-62 Inv. Overload Derate Current
95 %
All set-ups
TRUE
0
Uint16
14-8* Options
14-89 Option Detection
[0] Protect Option Config.
1 set-up
TRUE
–
Uint8
14-9* Fault Settings
14-90 Fault Level
ExpressionLimit
1 set-up
TRUE
–
Uint8
Parameter Lists
VLT® AutomationDrive FC 361
172
Danfoss A/S © 03/2019 All rights reserved.
MG06J202
5
5