1-75
Start Speed [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
1-76
Start Current
0 A
All set-ups
TRUE
-2
Uint32
1-77
Compressor Start Max Speed [RPM]
ExpressionLimit
All set-ups
TRUE
–
Uint16
1-78
Compressor Start Max Speed [Hz]
ExpressionLimit
All set-ups
TRUE
–
Uint16
1-79
Compressor Start Max Time to Trip
5 s
All set-ups
TRUE
0
Uint8
1-8* Stop Adjustments
1-80
Function at Stop
[0] Coast
All set-ups
TRUE
–
Uint8
1-81
Min Speed for Function at Stop [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
1-82
Min Speed for Function at Stop [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
1-9* Motor Temperature
1-90
Motor Thermal Protection
ExpressionLimit
All set-ups
TRUE
–
Uint8
1-91
Motor External Fan
ExpressionLimit
All set-ups
TRUE
–
Uint8
1-93
Thermistor Resource
[0] None
All set-ups
TRUE
–
Uint8
5.2.3 2-** Brakes
Param
eter
numb
er
Parameter description
Default value
4 set-up
Change
during
operation
Conversion
index
Type
2-0* DC-Brake
2-00
DC Hold Current
50 %
All set-ups
TRUE
0
Uint8
2-01
DC Brake Current
50 %
All set-ups
TRUE
0
Uint16
2-02
DC Braking Time
10 s
All set-ups
TRUE
-1
Uint16
2-03
DC Brake Cut In Speed [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
2-04
DC Brake Cut In Speed [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
2-06
Parking Current
50 %
All set-ups
TRUE
0
Uint16
2-07
Parking Time
3 s
All set-ups
TRUE
-1
Uint16
2-1* Brake Energy Funct.
2-10
Brake Function
ExpressionLimit
All set-ups
TRUE
–
Uint8
2-16
AC brake Max. Current
100 %
All set-ups
TRUE
-1
Uint32
2-17
Over-voltage Control
[0] Disabled
All set-ups
TRUE
–
Uint8
2-19
Over-voltage Gain
100 %
All set-ups
TRUE
0
Uint16
5.2.4 3-** Reference / Ramps
Param
eter
numb
er
Parameter description
Default value
4 set-up
Change
during
operation
Conversion
index
Type
3-0* Reference Limits
3-00
Reference Range
ExpressionLimit
All set-ups
TRUE
–
Uint8
3-01
Reference/Feedback Unit
ExpressionLimit
All set-ups
TRUE
–
Uint8
3-02
Minimum Reference
ExpressionLimit
All set-ups
TRUE
-3
Int32
3-03
Maximum Reference
ExpressionLimit
All set-ups
TRUE
-3
Int32
3-04
Reference Function
[0] Sum
All set-ups
TRUE
–
Uint8
3-1* References
3-10
Preset Reference
0 %
All set-ups
TRUE
-2
Int16
3-11
Jog Speed [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
3-12
Catch up/slow Down Value
0 %
All set-ups
TRUE
-2
Int16
3-13
Reference Site
[0] Linked to Hand / Auto
All set-ups
TRUE
–
Uint8
3-14
Preset Relative Reference
0 %
All set-ups
TRUE
-2
Int32
3-15
Reference Resource 1
[1] Analog Input 53
All set-ups
TRUE
–
Uint8
3-16
Reference Resource 2
ExpressionLimit
All set-ups
TRUE
–
Uint8
Parameter Lists
VLT® AutomationDrive FC 361
162
Danfoss A/S © 03/2019 All rights reserved.
MG06J202
5
5