5-11
Terminal 19 Digital Input
ExpressionLimit
All set-ups
TRUE
–
Uint8
5-12
Terminal 27 Digital Input
ExpressionLimit
All set-ups
TRUE
–
Uint8
5-13
Terminal 29 Digital Input
ExpressionLimit
All set-ups
TRUE
–
Uint8
5-14
Terminal 32 Digital Input
ExpressionLimit
All set-ups
TRUE
–
Uint8
5-15
Terminal 33 Digital Input
ExpressionLimit
All set-ups
TRUE
–
Uint8
5-16
Terminal X30/2 Digital Input
ExpressionLimit
All set-ups
TRUE
–
Uint8
5-17
Terminal X30/3 Digital Input
ExpressionLimit
All set-ups
TRUE
–
Uint8
5-18
Terminal X30/4 Digital Input
ExpressionLimit
All set-ups
TRUE
–
Uint8
5-3* Digital Outputs
5-30
Terminal 27 Digital Output
ExpressionLimit
All set-ups
TRUE
–
Uint8
5-31
Terminal 29 Digital Output
ExpressionLimit
All set-ups
TRUE
–
Uint8
5-32
Term X30/6 Digi Out (MCB 101)
[0] No operation
All set-ups
TRUE
–
Uint8
5-33
Term X30/7 Digi Out (MCB 101)
[0] No operation
All set-ups
TRUE
–
Uint8
5-4* Relays
5-40
Function Relay
ExpressionLimit
All set-ups
TRUE
–
Uint8
5-41
On Delay, Relay
0.01 s
All set-ups
TRUE
-2
Uint16
5-42
Off Delay, Relay
0.01 s
All set-ups
TRUE
-2
Uint16
5-5* Pulse Input
5-50
Term. 29 Low Frequency
100 Hz
All set-ups
TRUE
0
Uint32
5-51
Term. 29 High Frequency
ExpressionLimit
All set-ups
TRUE
0
Uint32
5-52
Term. 29 Low Ref./Feedb. Value
0 ReferenceFeedbackUnit
All set-ups
TRUE
-3
Int32
5-53
Term. 29 High Ref./Feedb. Value
ExpressionLimit
All set-ups
TRUE
-3
Int32
5-54
Pulse Filter Time Constant #29
100 ms
All set-ups
FALSE
-3
Uint16
5-55
Term. 33 Low Frequency
100 Hz
All set-ups
TRUE
0
Uint32
5-56
Term. 33 High Frequency
ExpressionLimit
All set-ups
TRUE
0
Uint32
5-57
Term. 33 Low Ref./Feedb. Value
0 ReferenceFeedbackUnit
All set-ups
TRUE
-3
Int32
5-58
Term. 33 High Ref./Feedb. Value
ExpressionLimit
All set-ups
TRUE
-3
Int32
5-59
Pulse Filter Time Constant #33
100 ms
All set-ups
FALSE
-3
Uint16
5-6* Pulse Output
5-60
Terminal 27 Pulse Output Variable
ExpressionLimit
All set-ups
TRUE
–
Uint8
5-62
Pulse Output Max Freq #27
ExpressionLimit
All set-ups
TRUE
0
Uint32
5-63
Terminal 29 Pulse Output Variable
ExpressionLimit
All set-ups
TRUE
–
Uint8
5-65
Pulse Output Max Freq #29
ExpressionLimit
All set-ups
TRUE
0
Uint32
5-66
Terminal X30/6 Pulse Output Variable
[0] No operation
All set-ups
TRUE
–
Uint8
5-68
Pulse Output Max Freq #X30/6
5000 Hz
All set-ups
TRUE
0
Uint32
5-7* 24V Encoder Input
5-70
Term 32/33 Pulses Per Revolution
1024 N/A
All set-ups
FALSE
0
Uint16
5-71
Term 32/33 Encoder Direction
[0] Clockwise
All set-ups
FALSE
–
Uint8
5-9* Bus Controlled
5-90
Digital & Relay Bus Control
0 N/A
All set-ups
TRUE
0
Uint32
5-93
Pulse Out #27 Bus Control
0 %
All set-ups
TRUE
-2
N2
5-94
Pulse Out #27 Timeout Preset
0 %
1 set-up
TRUE
-2
Uint16
5-95
Pulse Out #29 Bus Control
0 %
All set-ups
TRUE
-2
N2
5-96
Pulse Out #29 Timeout Preset
0 %
1 set-up
TRUE
-2
Uint16
5-97
Pulse Out #X30/6 Bus Control
0 %
All set-ups
TRUE
-2
N2
5-98
Pulse Out #X30/6 Timeout Preset
0 %
1 set-up
TRUE
-2
Uint16
Parameter Lists
Programming Guide
MG06J202
Danfoss A/S © 03/2019 All rights reserved.
165
5
5