3.1.12 Changing a Data Value
If the selected parameter shows a numeric data value,
change the selected data value with the [
◀
] [
▶
] navigation
keys and the [
▲
] [
▼
] navigation keys. Press [
◀
] [
▶
] keys to
move the cursor horizontally.
130BP069.10
1- 6*
113 RPM 1.78 A 1(1)
Load depen. setting
1 - 60 Low speed load
compensation
1
0
0%
Illustration 3.17 Changing a Data Value
Press the [
▲
] [
▼
] keys to change the data value. [
▲
]
increases the data value, and [
▼
] decreases the data value.
Place the cursor on the value to save and press [OK].
130BP070.10
1 - 60 Low speed load
compensation
1 0%
Load depen. setting
1- 6*
729RPM
6.21A
1(1)
6
Illustration 3.18 Saving a Data Value
3.1.13 Infinitely Variable Change of
Numeric Data Value
If the selected parameter shows a numeric data value,
select a digit with [
◀
] [
▶
].
130BP073.10
635 RPM
1 - 71 Start Delay
00.
0
s
0.44 A
1 (1)
1- 7*
Start Adjustments
Illustration 3.19 Selecting a Digit
Change the selected digit infinitely variably with [
▲
] [
▼
].
The cursor indicates the selected digit. Place the cursor on
the digit to save and press [OK].
130BP072.10
957RPM
1-71 High starting torque time
0. s
11.58A
1 (1)
1-7*
Start Adjustments
4
Illustration 3.20 Saving
3.1.14 Value, Step by Step
Certain parameters can be changed step by step. This
applies to:
•
Parameter 1-20 Motor Power [kW]
.
•
Parameter 1-22 Motor Voltage
.
•
Parameter 1-23 Motor Frequency
.
The parameters are changed both as a group of numeric
data values and as numeric data values that are infinitely
varying.
3.1.15 Readout and Programming of
Indexed Parameters
Parameters are indexed when placed in a rolling stack.
Parameter 15-30 Fault Log: Error Code
to
parameter 15-32 Alarm Log: Time
contain a fault log, which
can be read out. Select a parameter, press [OK], and press
the [
▲
] [
▼
] keys to scroll through the value log.
For example,
parameter 3-10 Preset Reference
is changed as
follows:
1.
Select the parameter, press [OK], and press [
▲
] [
▼
]
to scroll through the indexed values.
2.
To change the parameter value, select the
indexed value and press [OK].
3.
Change the value by pressing [
▲
] [
▼
].
4.
Press [OK] to accept the new setting.
5.
Press [Cancel] to abort. Press [Back] to leave the
parameter.
3.1.16 How to Program on the Numerical
Local Control Panel
The following instructions are valid for the numerical LCP
(LCP 101).
The control panel is divided into 4 functional groups:
•
Numerical display.
•
Menu keys and indicator lights - changing
parameters and switching between display
functions.
•
Navigation keys and indicator lights.
•
Operation keys and indicator lights.
Programming
VLT® AutomationDrive FC 361
20
Danfoss A/S © 03/2019 All rights reserved.
MG06J202
3
3
Summary of Contents for VLT AutomationDrive FC 361
Page 2: ......