1-04
Overload Mode
[1] Normal torque
All set-ups
FALSE
–
Uint8
1-05
Local Mode Configuration
[2] As mode par 1-00
All set-ups
TRUE
–
Uint8
1-06
Clockwise Direction
[0] Normal
All set-ups
FALSE
–
Uint8
1-1* Special Settings
1-10
Motor Construction
[0] Asynchron
All set-ups
FALSE
–
Uint8
1-14
Damping Gain
140 %
All set-ups
TRUE
0
Int16
1-15
Low Speed Filter Time Const.
ExpressionLimit
All set-ups
TRUE
-2
Uint16
1-16
High Speed Filter Time Const.
ExpressionLimit
All set-ups
TRUE
-2
Uint16
1-17
Voltage filter time const.
ExpressionLimit
All set-ups
TRUE
-3
Uint16
1-18
Min. Current at No Load
0 %
All set-ups
TRUE
0
Uint16
1-2* Motor Data
1-20
Motor Power [kW]
ExpressionLimit
All set-ups
FALSE
1
Uint32
1-22
Motor Voltage
ExpressionLimit
All set-ups
FALSE
0
Uint16
1-23
Motor Frequency
ExpressionLimit
All set-ups
FALSE
0
Uint16
1-24
Motor Current
ExpressionLimit
All set-ups
FALSE
-2
Uint32
1-25
Motor Nominal Speed
ExpressionLimit
All set-ups
FALSE
67
Uint16
1-26
Motor Cont. Rated Torque
ExpressionLimit
All set-ups
FALSE
-1
Uint32
1-29
Automatic Motor Adaptation (AMA)
[0] Off
All set-ups
FALSE
–
Uint8
1-3* Adv. Motor Data
1-30
Stator Resistance (Rs)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
1-31
Rotor Resistance (Rr)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
1-33
Stator Leakage Reactance (X1)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
1-34
Rotor Leakage Reactance (X2)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
1-35
Main Reactance (Xh)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
1-36
Iron Loss Resistance (Rfe)
ExpressionLimit
All set-ups
FALSE
-3
Uint32
1-37
d-axis Inductance (Ld)
ExpressionLimit
All set-ups
FALSE
-3
Int32
1-38
q-axis Inductance (Lq)
ExpressionLimit
All set-ups
FALSE
-3
Int32
1-39
Motor Poles
ExpressionLimit
All set-ups
FALSE
0
Uint8
1-40
Back EMF at 1000 RPM
ExpressionLimit
All set-ups
FALSE
0
Uint16
1-41
Motor Angle Offset
0 N/A
All set-ups
TRUE
0
Int16
1-46
Position Detection Gain
100 %
All set-ups
TRUE
0
Uint16
1-47
Torque Calibration
ExpressionLimit
All set-ups
TRUE
–
Uint8
1-5* Load Indep. Setting
1-50
Motor Magnetisation at Zero Speed
100 %
All set-ups
TRUE
0
Uint16
1-51
Min Speed Normal Magnetising [RPM]
ExpressionLimit
All set-ups
TRUE
0
Uint16
1-52
Min Speed Normal Magnetising [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
1-55
U/f Characteristic - U
ExpressionLimit
All set-ups
TRUE
0
Uint16
1-56
U/f Characteristic - F
ExpressionLimit
All set-ups
TRUE
0
Uint16
1-58
Flying Start Test Pulses Current
ExpressionLimit
All set-ups
FALSE
0
Uint16
1-59
Flying Start Test Pulses Frequency
ExpressionLimit
All set-ups
FALSE
0
Uint16
1-6* Load Depen. Setting
1-60
Low Speed Load Compensation
100 %
All set-ups
TRUE
0
Int16
1-61
High Speed Load Compensation
100 %
All set-ups
TRUE
0
Int16
1-62
Slip Compensation
ExpressionLimit
All set-ups
TRUE
0
Int16
1-63
Slip Compensation Time Constant
ExpressionLimit
All set-ups
TRUE
-2
Uint16
1-64
Resonance Damping
ExpressionLimit
All set-ups
TRUE
0
Uint16
1-65
Resonance Damping Time Constant
5 ms
All set-ups
TRUE
-3
Uint8
1-66
Min. Current at Low Speed
ExpressionLimit
All set-ups
TRUE
0
Uint32
1-7* Start Adjustments
1-70
Start Mode
[0] Rotor Detection
All set-ups
TRUE
–
Uint8
1-71
Start Delay
0 s
All set-ups
TRUE
-1
Uint8
1-72
Start Function
[2] Coast/delay time
All set-ups
TRUE
–
Uint8
1-73
Flying Start
ExpressionLimit
All set-ups
FALSE
–
Uint8
1-74
Start Speed [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
Parameter Lists
Programming Guide
MG06J202
Danfoss A/S © 03/2019 All rights reserved.
161
5
5