5.2.11 12-** Ethernet
Param
eter
numb
er
Parameter description
Default value
4 set-up
Change
during
operation
Conversion
index
Type
12-0* IP Settings
12-00 IP Address Assignment
ExpressionLimit
2 set-ups
TRUE
–
Uint8
12-01 IP Address
0 N/A
1 set-up
TRUE
0
OctStr[4]
12-02 Subnet Mask
0 N/A
1 set-up
TRUE
0
OctStr[4]
12-03 Default Gateway
0 N/A
1 set-up
TRUE
0
OctStr[4]
12-04 DHCP Server
0 N/A
2 set-ups
TRUE
0
OctStr[4]
12-05 Lease Expires
ExpressionLimit
All set-ups
TRUE
0
TimD
12-06 Name Servers
0 N/A
1 set-up
TRUE
0
OctStr[4]
12-07 Domain Name
0 N/A
1 set-up
TRUE
0
VisStr[48]
12-08 Host Name
0 N/A
1 set-up
TRUE
0
VisStr[48]
12-09 Physical Address
0 N/A
1 set-up
TRUE
0
VisStr[17]
12-1* Ethernet Link Parameters
12-10 Link Status
[0] No Link
All set-ups
TRUE
–
Uint8
12-11 Link Duration
ExpressionLimit
All set-ups
TRUE
0
TimD
12-12 Auto Negotiation
ExpressionLimit
2 set-ups
TRUE
–
Uint8
12-13 Link Speed
ExpressionLimit
2 set-ups
TRUE
–
Uint8
12-14 Link Duplex
ExpressionLimit
2 set-ups
TRUE
–
Uint8
12-18 Supervisor MAC
0 N/A
2 set-ups
TRUE
0
OctStr[6]
12-19 Supervisor IP Addr.
0 N/A
2 set-ups
TRUE
0
OctStr[4]
12-8* Other Ethernet Services
12-80 FTP Server
[0] Disabled
2 set-ups
TRUE
–
Uint8
12-81 HTTP Server
[0] Disabled
2 set-ups
TRUE
–
Uint8
12-82 SMTP Service
[0] Disabled
2 set-ups
TRUE
–
Uint8
12-83 SNMP Agent
[1] Enabled
2 set-ups
TRUE
–
Uint8
12-84 Address Conflict Detection
[1] Enabled
2 set-ups
TRUE
–
Uint8
12-85 ACD Last Conflict
0 N/A
2 set-ups
TRUE
0
OctStr[35]
12-89 Transparent Socket Channel Port
ExpressionLimit
2 set-ups
TRUE
0
Uint16
12-9* Advanced Ethernet Services
12-90 Cable Diagnostic
[0] Disabled
2 set-ups
TRUE
–
Uint8
12-91 Auto Cross Over
[1] Enabled
2 set-ups
TRUE
–
Uint8
12-92 IGMP Snooping
[1] Enabled
2 set-ups
TRUE
–
Uint8
12-93 Cable Error Length
0 N/A
1 set-up
TRUE
0
Uint16
12-94 Broadcast Storm Protection
-1 %
2 set-ups
TRUE
0
Int8
12-95 Inactivity timeout
120 N/A
2 set-ups
TRUE
0
Uint16
12-96 Port Config
ExpressionLimit
2 set-ups
TRUE
–
Uint8
12-97 QoS Priority
ExpressionLimit
2 set-ups
TRUE
0
Int8
12-98 Interface Counters
4000 N/A
All set-ups
TRUE
0
Uint32
12-99 Media Counters
0 N/A
All set-ups
TRUE
0
Uint32
Parameter Lists