16-63 Terminal 54 Switch Setting
[0] Current
All set-ups
FALSE
–
Uint8
16-64 Analog Input 54
0 N/A
All set-ups
FALSE
-3
Int32
16-65 Analog Output 42 [mA]
0 N/A
All set-ups
FALSE
-3
Int16
16-66 Digital Output [bin]
0 N/A
All set-ups
FALSE
0
Int16
16-67 Freq. Input #29 [Hz]
0 N/A
All set-ups
FALSE
0
Int32
16-68 Freq. Input #33 [Hz]
0 N/A
All set-ups
FALSE
0
Int32
16-69 Pulse Output #27 [Hz]
0 N/A
All set-ups
FALSE
0
Int32
16-70 Pulse Output #29 [Hz]
0 N/A
All set-ups
FALSE
0
Int32
16-71 Relay Output [bin]
0 N/A
All set-ups
FALSE
0
Int16
16-72 Counter A
0 N/A
All set-ups
TRUE
0
Int32
16-73 Counter B
0 N/A
All set-ups
TRUE
0
Int32
16-75 Analog In X30/11
0 N/A
All set-ups
FALSE
-3
Int32
16-76 Analog In X30/12
0 N/A
All set-ups
FALSE
-3
Int32
16-77 Analog Out X30/8 [mA]
0 N/A
All set-ups
FALSE
-3
Int16
16-8* Fieldbus & FC Port
16-80 Fieldbus CTW 1
0 N/A
All set-ups
FALSE
0
V2
16-82 Fieldbus REF 1
0 N/A
All set-ups
FALSE
0
N2
16-84 Comm. Option STW
0 N/A
All set-ups
FALSE
0
V2
16-85 FC Port CTW 1
0 N/A
All set-ups
FALSE
0
V2
16-86 FC Port REF 1
0 N/A
All set-ups
FALSE
0
N2
16-87 Bus Readout Alarm/Warning
0 N/A
All set-ups
FALSE
0
Uint16
16-9* Diagnosis Readouts
16-90 Alarm Word
0 N/A
All set-ups
FALSE
0
Uint32
16-91 Alarm Word 2
0 N/A
All set-ups
FALSE
0
Uint32
16-92 Warning Word
0 N/A
All set-ups
FALSE
0
Uint32
16-93 Warning Word 2
0 N/A
All set-ups
FALSE
0
Uint32
16-94 Ext. Status Word
0 N/A
All set-ups
FALSE
0
Uint32
16-95 Ext. Status Word 2
0 N/A
All set-ups
FALSE
0
Uint32
16-97 Alarm Word 3
0 N/A
All set-ups
FALSE
0
Uint32
16-98 Warning Word 3
0 N/A
All set-ups
FALSE
0
Uint32
5.2.16 17-** Position Feedback
Param
eter
numb
er
Parameter description
Default value
4 set-up
Change
during
operation
Conversion
index
Type
17-1* Inc. Enc. Interface
17-10 Signal Type
[1] RS422 (5V TTL)
All set-ups
FALSE
–
Uint8
17-11 Resolution (PPR)
1024 N/A
All set-ups
FALSE
0
Uint16
17-5* Resolver Interface
17-50 Poles
2 N/A
1 set-up
FALSE
0
Uint8
17-51 Input Voltage
7 V
1 set-up
FALSE
-1
Uint8
17-52 Input Frequency
10 kHz
1 set-up
FALSE
2
Uint8
17-53 Transformation Ratio
0.5 N/A
1 set-up
FALSE
-1
Uint8
17-56 Encoder Sim. Resolution
[0] Disabled
1 set-up
FALSE
–
Uint8
17-59 Resolver Interface
[0] Disabled
2 set-ups
FALSE
–
Uint8
17-6* Monitoring and App.
17-60 Feedback Direction
[0] Clockwise
All set-ups
FALSE
–
Uint8
17-61 Feedback Signal Monitoring
[1] Warning
All set-ups
TRUE
–
Uint8
Parameter Lists
Programming Guide
MG06J202
Danfoss A/S © 03/2019 All rights reserved.