![background image](http://html1.mh-extra.com/html/daikin/rxta30b2v1b/rxta30b2v1b_service-manual_4215663189.webp)
4
|
Components
Service manual
189
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
b
a
c
d
c
a
Rod
b
Link
c
Screw (swing raster motor fixation)
d
Swing raster motor
9
Remove the 2 screws that fix the swing raster motor to the bracket.
10
Remove the swing raster motor.
11
Disconnect the wiring harness from the swing raster motor.
12
To install the swing raster motor, see
FTXTM40R
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
144].
2
Put a small drain pan (or container) under the drain hose.
3
Remove the screw from the fixation bracket and pull the drain hose
downwards to remove it from the indoor unit.
a
b
a
Screw (drain hose)
b
Drain hose
4
Remove the swing raster motor cover.