![background image](http://html1.mh-extra.com/html/daikin/rxta30b2v1b/rxta30b2v1b_service-manual_4215663203.webp)
4
|
Components
Service manual
203
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
b
a
a
Display PCB
b
Indication lamp cover
3
Install the indication lamp cover in the correct location on the indoor unit.
4
Install the display panel.
▪
FTXTP-M AND ATXTP-M UNITS
As the indoor unit air (room) thermistor is located on the display PCB, install the
display PCB as described in the steps below:
1
Install the display PCB in the correct location on the unit.
2
Connect the connector to the display PCB.
Other refrigerant side thermistors
1
Install the thermistor in the thermistor holder as follows:
▪
For outdoor unit air (ambient) thermistor:
Correctly install the thermistor in the holder and close the thermistor holder.
▪
For refrigerant piping thermistors:
Pull the clip and install the thermistor in the specific thermistor holder. Make
sure the clip is in the correct position (blocking the thermistor).
c
a
b