Pulses are measured during fan blade
propeller rotation?
Action
Yes
Perform a check of the main PCB, see
No
Replace the DC fan motor, see
4.15.2 Repair procedures
To remove the propeller fan blade assembly
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
1
Remove the required plate work, see
144].
2
Remove the nut that fixes the propeller fan blade assembly.
a
b
a
Nut
b
Propeller fan blade assembly
3
Pull and remove the propeller fan blade assembly from the DC fan motor
assembly.
INFORMATION
Use a pulley remover if the propeller cannot be removed manually.
4
To install the propeller fan blade assembly, see
To remove the DC fan motor assembly
1
Remove the propeller fan blade assembly from the DC fan motor assembly,
see
DANGER: RISK OF ELECTROCUTION
Wait for at least 10 minutes after the circuit breaker has been turned OFF, to be sure
the rectifier voltage is below 10 V DC before proceeding.
2
Disconnect the DC fan motor connector from the main PCB.
3
Cut the tie strap.