4
|
Components
Service manual
179
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
a
b
c
a
Screw (drain hose)
b
Drain hose
c
Swing raster motor cover
3
Install the drain hose on the indoor unit.
4
Install the drain hose fixation bracket. Install and tighten the screw.
5
Install the swing flap motor, see
Is the problem solved?
Action
Yes
No further actions required.
No
Return to the troubleshooting of the
specific error and continue with the
next procedure.
FTXTA-B units
INFORMATION
To replace the motor, the complete gearcase assembly MUST be replaced.
As the main swing flap motor wiring harness is part of the secondary swing flap
motor gearcase assembly, see
181] to replace the wiring
harness.
To remove the swing flap motor gearcase assembly
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
Remove the main swing flap from the indoor unit (by clicking it out).
2
Remove the 2 screws and remove the swing flap motor gearcase assembly
from the indoor unit.