4
|
Components
Service manual
96
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
B
FTXTM30R units
C
FTXTM40R units
D
FTXTP-M + ATXTP-M units
a
Screw
b
Streamer unit assembly
c
Indoor unit heat exchanger
10
Lift and remove the indoor unit heat exchanger from the unit.
11
To install the indoor unit heat exchanger, see
95].
To install the indoor unit heat exchanger
1
Install the indoor unit heat exchanger in the correct location on the indoor
unit.
2
Install and tighten the screws to fix the heat exchanger to the side plate.
a
B
A
a
a
b
c
a c
a
D
a c
C
a
b
c
a
A
FTXTA-B units
B
FTXTM30R units
C
FTXTM40R units
D
FTXTP-M + ATXTP-M units
a
Screw
b
Streamer unit assembly
c
Indoor unit heat exchanger
3
Install the indoor unit fan motor, see
4
For FTXTM-R units ONLY: Install the streamer unit assembly in the correct
location. Install and tighten the screw to fix the streamer unit assembly.
5
144].
6
Install the indoor unit in the correct location on the wall. Install and tighten
the screw to fix the indoor unit to the installation plate (mounting plate).
7
Make sure that the refrigerant field piping connections are clean and not
damaged. Remove the caps and properly connect the field piping to the liquid
and gas pipes of the indoor unit. Tighten the flared joints.
8
Correctly install the insulation on the liquid and gas pipes.
9
Connect the wiring to the wiring terminals of the indoor unit.