![background image](http://html1.mh-extra.com/html/daikin/rxta30b2v1b/rxta30b2v1b_service-manual_4215663187.webp)
4
|
Components
Service manual
187
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
a
b
c
a
Swing raster motor cover
b
Swing raster motor assembly
c
Screw
3
Remove the 2 screws that fix the swing raster motor assembly to the indoor
unit.
4
Disconnect the swing raster shaft from the swing raster motor rod.
c
b
a
a
Swing raster shaft
b
Swing raster motor rod
c
Swing raster motor assembly
5
Remove the swing raster motor assembly from the indoor unit.
6
Remove the 2 screws that fix the swing raster motor to the bracket.
7
Disconnect the rod from the swing raster motor and remove the motor. Keep
the rod and bracket for reuse.
8
To install the swing raster motor, see
FTXTM30R
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
144].
2
Put a small drain pan (or container) under the drain hose.