![background image](http://html1.mh-extra.com/html/daikin/rxta30b2v1b/rxta30b2v1b_service-manual_4215663070.webp)
4
|
Components
Service manual
70
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
Prerequisite:
Remove the required plate work, see
144].
Prerequisite:
Remove the compressor insulation.
1
Remove the cover of the compressor wire terminals.
a
a
Compressor wire terminals cover
2
Remove the compressor thermal protector with bracket from the compressor
housing.
a
b
c
a
Compressor thermal protector
b
Faston connector
c
Bracket
3
Disconnect the Faston connectors from the compressor thermal protector.
4
Separate the compressor thermal protector and the compressor thermal
protector bracket.