4
|
Components
Service manual
150
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
f
a
d
c
b
e
a
Electrical power supply wiring
b
Wire terminals
c
Screws
d
Wire clamp
e
Screws
f
Right side plate assembly
3
Connect the electrical power supply wiring to the wire terminals.
4
Install the wire clamp and fix it using the screws.
5
Connect all connectors to the main PCB.
INFORMATION
Use the wiring diagram and connection diagram for correct installation of the
connectors, see
232].
WARNING
When reconnecting a connector to the PCB, make sure to connect it on the correct
location and do NOT apply force, as this may damage the connector or connector
pins of the PCB.
6
Fix the wiring to the switch box using a new cable tie.