7
|
Technical data
Service manual
248
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
7.4 Component overview
7.4.1 Component overview: Outdoor unit
c
l
b
a
e
d
g
m
i j k
q r
o
n
p
l
s
f
h
a
Fan
k
Muffler with filter
b
Fan motor M1F
l
Accumulator
c
Muffler
m
4‑way valve body
d
Discharge pipe thermistor R3T
n
Air thermistor R1T
e
Compressor M1C
o
Heat exchanger
f
High pressure switch S1PH
p
Muffler
g
Main PCB
q
Stop valve (liquid)
h
4‑way valve coil Y1S
r
Stop valve with service port (gas)
i
Expansion valve Y1E
s
Heat exchanger thermistor R2T
j
Muffler