background image

DAIKIN ROOM AIR CONDITIONER

INSTALLATION MANUAL

R32 Split Series

English

De

ut

sch

Fra

n

ça

is

Русский

Dansk

Sven

ska

Norsk

Su

om

i

Polski

Models

FTXTP25K3V1B
FTXTP35K3V1B
ATXTP25K3V1B
ATXTP35K3V1B

3PEN482320-6B.book  Page 1  Wednesday, July 12, 2017  2:30 PM

Summary of Contents for ATXTP25K3V1B

Page 1: ...DITIONER INSTALLATION MANUAL R32 Split Series English Deutsch Fran ais Dansk Svenska Norsk Suomi Polski Models FTXTP25K3V1B FTXTP35K3V1B ATXTP25K3V1B ATXTP35K3V1B 3PEN482320 6B book Page 1 Wednesday J...

Page 2: ...B de acuerdo con el Certificado C 06 Nota delineato nel A e giudicato positivamente da B secondo il Certificato C 07 A B C 08 Nota tal como estabelecido em A e com o parecer positivo de B de acordo co...

Page 3: ...up or fire When wiring the power supply and connecting the wiring between the indoor and outdoor units position the wires so that the control box lid can be securely fastened Improper positioning of t...

Page 4: ...inage and insulate piping to prevent condensation Improper drain piping may result in indoor water leakage and property damage Tighten the flare nut according to the specified method such as with a to...

Page 5: ...warm air is circulated throughout the room 7 the unit is away from electronic ignition type fluorescent lamps inverter or rapid start type as they may shorten the remote controller range 8 the unit is...

Page 6: ...under the centre of the front grille and while pushing up pull it toward you Installation method 1 Install the front grille and firmly engage the upper hooks 3 locations 2 Install 3 screws of the fro...

Page 7: ...l wiring cover as it was and pull the harness around as shown in the figure Removal method of metal plate electrical wiring covers 1 Remove the front grille 2 Remove the electrical wiring box 1 screw...

Page 8: ...or unit Push up the marked area at the lower part of the front grille to release the hooks If it is difficult to release remove the front grille 30mm or more from ceiling Front panel 50mm or more from...

Page 9: ...ll cover in the feed through hole to prevent possible heat electrical shock or fire Be sure to caulk the gaps around the pipes with caulking material to prevent water leakage 1 Bore a feed through hol...

Page 10: ...ce 2 After cutting off the pipe port cover perform filing Remove the burrs along the cut section using a half round needle file CAUTION If the pipe port cover is cut off using nippers the front grille...

Page 11: ...hose Replacing onto the left side 1 Remove the insulation fixing screw on the right and remove the drain hose 2 Remove the drain plug on the left side and attach it to the right side 3 Insert the drai...

Page 12: ...l it is firmly caught by the mounting plate hooks Secure indoor unit to the mounting plate with indoor unit fixing screws M4 12L 3 3 Wall embedded piping Follow the instructions given under left side...

Page 13: ..._A MR _B S U V W X A K R_ CONNECTION CONNECTOR Q L OVERLOAD PROTECTOR D V D DIODE Q M THERMOSWITCH DB DIODEBRIDGE R RESISTOR DS DIP SWITCH R T THERMISTOR E H HEATER RC RECEIVER F U FU FOR CHARACTERIS...

Page 14: ...dded drain piping is required use appropriate parts that match the hose front end Figure of hose front end 4 When extending the drain hose use a commercially available extension hose with an inner dia...

Page 15: ...dryer to this R32 unit in order to guarantee its lifetime The drying material may dissolve and damage the system Protect or enclose the refrigerant tubing to avoid mechanical damage Incomplete flarin...

Page 16: ...10 C max Choose heat insulation materials that will withstand this temperature 2 Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below 3 Use separate thermal...

Page 17: ...To stop the operation press Some of the functions cannot be used in the trial operation mode The air conditioner draws a small amount of power in its standby mode If the system is not to be used for...

Page 18: ...3PEN482320 6B book Page 1 Wednesday July 12 2017 2 30 PM...

Page 19: ...3PEN482320 6B book Page 2 Wednesday July 12 2017 2 30 PM...

Page 20: ...3P482320 6B 2017 06 Copyright 2017 Daikin 3PEN482320 6B book Page 1 Wednesday July 12 2017 2 30 PM...

Reviews: