Is the problem solved?
Action
No
Return to
126] of the PCB and
continue with the next procedure.
To check the fuse of the main PCB
Prerequisite:
First perform all earlier main PCB checks, see
126].
1
Measure the continuity of the fuse. If no continuity is measured, the fuse has
blown.
a
a
a
a
Fuse
Blown fuse on the main PCB?
Action
Yes
Replace the blown fuse, see
132].
No
Return to
126] of the main PCB
and continue with the next procedure.
To check the rectifier voltage of the main PCB
Prerequisite:
First perform all earlier main PCB checks, see
126].
1
Turn ON the power of the unit.
2
Measure the voltage on the rectifier voltage check terminals (+ and –) on the
main PCB.
Result:
The measured voltage MUST be approximately 324 V DC.
a
b
a
+ terminal
b
– terminal