4
|
Components
Service manual
194
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
5
Install and tighten the 2 screws to fix the swing raster motor to the bracket.
6
Install the swing raster motor assembly on the correct location on the indoor
unit while guiding the rod inside the swing raster compartment.
7
Install the 2 screws to fix the swing raster motor assembly. Do NOT yet tighten
the screws.
e
d
c
a
b
c
a
Swing raster motor cover
b
Swing raster motor assembly
c
Screw (swing raster motor assembly)
d
Fan guard
e
Swing raster motor rod
8
Connect the swing raster motor rod to the swing raster shaft using soft tools.
9
Tighten the 2 screws to properly fix the swing raster motor assembly.
10
Install the fan guard.
11
Install the swing raster motor cover.
12
Connect the drain hose to the indoor unit.
a
b
a
Screw (drain hose)
b
Drain hose
13
Install the drain hose fixation bracket. Install and tighten the screw.
14
144].
Is the problem solved?
Action
Yes
No further actions required.