![background image](http://html1.mh-extra.com/html/daikin/rxta30b2v1b/rxta30b2v1b_service-manual_4215663146.webp)
4
|
Components
Service manual
146
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
a
Screw
b
Front plate
2
Remove the front plate.
To remove the side plate
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the refrigerant connection cover, top plate and front plate,
1
Remove the screw that fix the terminal protection plate and remove the plate.
a b
c
d e
a
Screw (terminal protection plate)
b
Terminal protection plate
c
Wire terminals
d
Screw (wire clamp)
e
Wire clamp
2
Disconnect the electrical power supply wiring from the wire terminals.
3
Remove the 3 screws that fix the wire clamp.
4
Remove the wire clamp.
5
Remove the air thermistor out of the guard net and the side plate.
d
c
d
d
d
c a b
a
Air thermistor
b
Guard net
c
Side plate
d
Screw (side plate)
6
Remove the screws that fix the right side plate assembly.
7
Remove the side plate assembly.
Summary of Contents for RXTA30B2V1B
Page 262: ......
Page 263: ......
Page 264: ...ESIE21 12A 2022 02 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...