4
|
Components
Service manual
125
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
To remove the intelligent thermal sensor wiring harness
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
Carefully click the complete intelligent thermal sensor assembly out of the
indoor unit.
a
a
Intelligent thermal sensor assembly
2
Disconnect the wiring harness from the intelligent thermal sensor PCB.
3
Disconnect the wiring harness connector from the indoor unit main PCB.
4
Cut all tie straps (if any) that fix the wiring harness.
5
Route the wiring harness out of the harness retainers and remove the
intelligent thermal sensor wiring harness.
6
To install the intelligent thermal sensor wiring harness, see
123].
To install the intelligent thermal sensor wiring harness
1
Connect the wiring harness connector to the indoor unit main PCB.
WARNING
When reconnecting a connector to the PCB, make sure to connect it on the correct
location and do NOT apply force, as this may damage the connector or connector
pins of the PCB.
2
Connect the wiring harness to the intelligent thermal sensor PCB.
3
Route the wiring harness along the harness retainers on the intelligent
thermal sensor assembly.
4
Click the intelligent thermal sensor assembly on the indoor unit.
Summary of Contents for RXTA30B2V1B
Page 262: ......
Page 263: ......
Page 264: ...ESIE21 12A 2022 02 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...