background image

SPLIT SYSTEM

Air Conditioners

SYSTEM

Air Conditioners

OPERATION MANUAL

MODELS

(Ceiling Suspended type)

SPLIT SYSTEM

VRV SYSTEM

FHQ35CAVEB

FXHQ32AVEB

FHQ50CAVEB

FXHQ63AVEB

FHQ60CAVEB

FXHQ100AVEB

FHQ71CAVEB
FHQ100CAVEB
FHQ125CAVEB
FHQ140CAVEB

FHQ140CAVEA

English

Deutsch

Français

Español

Italiano

Ελληνικά

Nederlands

Português

Русский

Türkçe

00_CV_3P303408-2N_01.fm  Page 1  Monday, February 17, 2014  9:23 AM

Summary of Contents for FHQ35CAVEB

Page 1: ...ded type SPLIT SYSTEM VRV SYSTEM FHQ35CAVEB FXHQ32AVEB FHQ50CAVEB FXHQ63AVEB FHQ60CAVEB FXHQ100AVEB FHQ71CAVEB FHQ100CAVEB FHQ125CAVEB FHQ140CAVEB FHQ140CAVEA English Deutsch Fran ais Espa ol Italiano...

Page 2: ...interior consulte tambi n los manu ales de instrucciones suministrados con la unidad exterior y el mando a distancia Vi ringraziamo per aver acquistato questo prodotto Per garantire un corretto funzi...

Page 3: ...es debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalaciones especiali zadas para su re...

Page 4: ...es a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or modera...

Page 5: ...e amount of any leaked refrigerant does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion CAUTION Children should be watched s...

Page 6: ...the control box fan motor drain pump etc make sure to shut off all power sup ply for the air conditioner including both indoor and outdoor units When cleaning the heat exchanger make sure to remove th...

Page 7: ...remote controller con trols one indoor unit system Confirm the following if your unit is of the following control system type Group control system One remote controller controls up to 16 indoor units...

Page 8: ...ch mineral oil such as cutting oil b Where there is much salt such as a beach area c Where sulfured gas exists such as a hot spring resort d Where there are considerable voltage fluctua tions such as...

Page 9: ...nerally takes a longer time for indoor temper ature of the HEATING OPERATION to reach the set temperature compared to the COOLING OPERATION It is advisable to start operation in advance using the TIME...

Page 10: ...the PROGRAM DRY OPERATION When the indoor temperature is lowered airflow from the air condi tioner may stop When operating continuously at downward airflow direction air blows in the automatically se...

Page 11: ...n Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle them Working while the blade is mov...

Page 12: ...ut your fingers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured 8 MAINTENANCE FOR SERVICE PERSONNEL CAUTION Do not wash the air cond...

Page 13: ...r After the air filter is cleaned return the air filter to the original place as it was attached before 5 Close the suction grille Slide all the knobs in the reverse order men tioned in the Clause 1 a...

Page 14: ...ped off dip the cloth in the neutral detergent diluted with water and twist the cloth After wiping off stain with this cloth wipe them with dry cloth NOTE Do not use such as gasoline benzine thinner p...

Page 15: ...the power is supplied to the air conditioner Some models perform the following operation to protect the devices If the HEATING OPERATION is performed within 6 hours after the power is supplied to the...

Page 16: ...n speed changes Raise the set temperature After a while the fan speed changes IV THE AIRFLOW DIRECTION IS DIFFERENT FROM THE SETTING OR THE AIRFLOW DIRECTION IS DIFFERENT FROM THE DIS PLAY ON THE REMO...

Page 17: ...st absorbed by the unit blows out IX THE INDOOR UNITS GIVE OFF ODORS During operation The unit absorbs the smell of rooms furni ture cigarettes etc and then emits them If odor is a concern you can set...

Page 18: ...and discharge direction Check if the airflow direction is not proper Set to an appropriate temperature fan speed and discharge direction Check if the doors or the windows are open Shut doors or windo...

Page 19: ...1D Measure Notify your local dealer and inform malfunction code of the display 10 2 FXHQ Read the operation manual attached to the out door unit UNIT No C L H OPERATION lamp INSPECTION display MALFUNC...

Page 20: ...3P303408 2N EM12A007B 1404 HT 00_CV_3P303408 2N_01 fm Page 2 Monday February 17 2014 9 23 AM...

Reviews: