Regarding outside air temperature and heat-
ing capacity

The heating capacity of the air conditioner 
declines as the outside air temperature falls. In 
such a case, use the air conditioner in combina-
tion with other heating systems.
(When a combustion appliance is used, ventilate 
the room regularly.)
Do not use the combustion appliance where the air 
from the air conditioner is blown directly toward it.

When the warm air stays under the ceiling and 
your feet are cold, we recommend that you use a 
circulator (a fan to circulate the air inside the 
room). For details, consult your local dealer.

When the indoor temperature exceeds the set 
temperature, the indoor unit discharges a gentle 
breeze (switches to gentle wind). The airflow 
direction becomes horizontal. (The remote con-
troller displays the fan speed and airflow direction 
that are set.)

CHARACTERISTICS OF THE PROGRAM 
DRY OPERATION

This operation lowers the humidity without lower-
ing the indoor temperature. The indoor tempera-
ture when the operation button is pressed will be 
the set temperature. At this time, the fan speed 
and temperature are set automatically, so the 
remote controller does not display the fan speed 
and set temperature.
To efficiently lower the indoor temperature and 
humidity, first use the COOLING OPERATION to 
lower the indoor temperature, and then use the 
PROGRAM DRY OPERATION. When the indoor 
temperature is lowered, airflow from the air condi-
tioner may stop.

When operating continuously at downward airflow 
direction, air blows in the automatically set direc-
tion for a period of time to prevent condensation on 
the horizontal blade. (The remote controller dis-
plays the airflow direction that is set.)

If the PROGRAM DRY OPERATION is used when 
the indoor temperature is low, frost forms the heat 
exchanger of the indoor unit. In this case, the air 
conditioner automatically switches to the 
DEFROST OPERATION for a while.
The low fan speed or a gentle wind is used to pre-
vent the discharge of melt water.

SOUND PRESSURE LEVEL

Sound pressure level is less than 70 dB(A).

AIRFLOW DIRECTION ADJUST

There are 2 ways of adjusting the airflow direction.
(When the operation stops, the horizontal blades 
at the air outlet (Up and down direction adjust-
ment blades) close automatically.)

1.

A. Up and down direction

2.

B. Left and right direction

A. UP AND DOWN DIRECTION

Press the AIRFLOW DIRECTION ADJUST 
button to select the air direction as following.

The AIRFLOW DIRECTION dis-
play swings as shown the left and 
the airflow direction continuously 
varies. (Automatic swing setting)

Press AIRFLOW DIRECTION 
ADJUST button to select the air 
direction of your choice.

The AIRFLOW DIRECTION dis-
play stops swinging and the air-
flow direction is fixed (Fixed 
airflow direction setting).

A. Up and down
    direction

B. Left and right direction

Fig. 2

swing

01_EN_3P303408-2N.fm  Page 7  Thursday, February 20, 2014  3:49 PM

Summary of Contents for FHQ35CAVEB

Page 1: ...ded type SPLIT SYSTEM VRV SYSTEM FHQ35CAVEB FXHQ32AVEB FHQ50CAVEB FXHQ63AVEB FHQ60CAVEB FXHQ100AVEB FHQ71CAVEB FHQ100CAVEB FHQ125CAVEB FHQ140CAVEB FHQ140CAVEA English Deutsch Fran ais Espa ol Italiano...

Page 2: ...interior consulte tambi n los manu ales de instrucciones suministrados con la unidad exterior y el mando a distancia Vi ringraziamo per aver acquistato questo prodotto Per garantire un corretto funzi...

Page 3: ...es debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalaciones especiali zadas para su re...

Page 4: ...es a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or modera...

Page 5: ...e amount of any leaked refrigerant does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion CAUTION Children should be watched s...

Page 6: ...the control box fan motor drain pump etc make sure to shut off all power sup ply for the air conditioner including both indoor and outdoor units When cleaning the heat exchanger make sure to remove th...

Page 7: ...remote controller con trols one indoor unit system Confirm the following if your unit is of the following control system type Group control system One remote controller controls up to 16 indoor units...

Page 8: ...ch mineral oil such as cutting oil b Where there is much salt such as a beach area c Where sulfured gas exists such as a hot spring resort d Where there are considerable voltage fluctua tions such as...

Page 9: ...nerally takes a longer time for indoor temper ature of the HEATING OPERATION to reach the set temperature compared to the COOLING OPERATION It is advisable to start operation in advance using the TIME...

Page 10: ...the PROGRAM DRY OPERATION When the indoor temperature is lowered airflow from the air condi tioner may stop When operating continuously at downward airflow direction air blows in the automatically se...

Page 11: ...n Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle them Working while the blade is mov...

Page 12: ...ut your fingers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured 8 MAINTENANCE FOR SERVICE PERSONNEL CAUTION Do not wash the air cond...

Page 13: ...r After the air filter is cleaned return the air filter to the original place as it was attached before 5 Close the suction grille Slide all the knobs in the reverse order men tioned in the Clause 1 a...

Page 14: ...ped off dip the cloth in the neutral detergent diluted with water and twist the cloth After wiping off stain with this cloth wipe them with dry cloth NOTE Do not use such as gasoline benzine thinner p...

Page 15: ...the power is supplied to the air conditioner Some models perform the following operation to protect the devices If the HEATING OPERATION is performed within 6 hours after the power is supplied to the...

Page 16: ...n speed changes Raise the set temperature After a while the fan speed changes IV THE AIRFLOW DIRECTION IS DIFFERENT FROM THE SETTING OR THE AIRFLOW DIRECTION IS DIFFERENT FROM THE DIS PLAY ON THE REMO...

Page 17: ...st absorbed by the unit blows out IX THE INDOOR UNITS GIVE OFF ODORS During operation The unit absorbs the smell of rooms furni ture cigarettes etc and then emits them If odor is a concern you can set...

Page 18: ...and discharge direction Check if the airflow direction is not proper Set to an appropriate temperature fan speed and discharge direction Check if the doors or the windows are open Shut doors or windo...

Page 19: ...1D Measure Notify your local dealer and inform malfunction code of the display 10 2 FXHQ Read the operation manual attached to the out door unit UNIT No C L H OPERATION lamp INSPECTION display MALFUNC...

Page 20: ...3P303408 2N EM12A007B 1404 HT 00_CV_3P303408 2N_01 fm Page 2 Monday February 17 2014 9 23 AM...

Reviews: