background image

5

English

If the temperature or the humidity is beyond the following condi-
tions, safety devices may work and the air conditioner may not 
operate, or sometimes, water may drop from the indoor unit.

3-1. FHQ

COOLING                                                            [°C]

HEATING                                                             [°C]

* To avoid condensation and water dripping out the indoor unit.

DB: Dry bulb temperature
WB: Wet bulb temperature

   The setting temperature range of the remote con-

troller is 16°C to 32°C.

3-2. FXHQ

Read the operation manual attached to the out-
door unit.

3. OPERATION RANGE

OUTDOOR 

UNIT

INDOOR

OUTDOOR 

TEMPERATURE

TEMPERATURE HUMIDITY

RN50
RN60

DB 21 to 37 80%*or 

below

DB 19.4 to 46

WB 14 to 28

RKS35 · 50 · 60
RXS35 · 50 · 60

DB 21 to 32 80%*or 

below

DB – 10 to 46

WB 14 to 28

4MKS58 · 75
3MXS52 · 68
4MXS68 · 80
5MXS90

DB 21 to 37

80%*or 

below

DB – 10 to 46

WB 14 to 28

5MKS90

DB 21 to 37 80%*or 

below

DB 10 to 46

WB 14 to 28

RZQ 140 · 200 ·

250

DB 21 to 37 80%*or 

below

DB – 5 to 46

WB 14 to 28

RZQG71 · 100 ·

125 · 140

DB 18 to 37 80%*or 

below

DB – 15 to 50

WB 12 to 28

RZQSG 71 · 100 ·

125 · 140

DB 21 to 37 80%*or 

below

DB – 10 to 43

WB 14 to 28

OUTDOOR 

UNIT

INDOOR

TEMPERATURE

OUTDOOR 

TEMPERATURE

RXS35 · 50 · 60

DB 10 to 30

DB

– 14 to 24

WB

– 15 to 18

3MXS52 · 68
4MXS68 · 80
5MXS90

DB 10 to 30

DB

– 14 to 21

WB – 15 to 15.5

RZQG 71 · 100 ·

125 · 140

DB 10 to 27

DB –19.5 to 21

WB –20 to 15.5

RZQ200 · 250

DB 10 to 27

DB

– 14 to 21

WB

– 15 to 15

RZQSG71

DB 10 to 30

DB – 14 to 21

WB –15 to 15.5

RZQSG 100 ·

125 · 140

DB 10 to 28

DB – 14 to 21

WB –15 to 15.5

RZQ140

DB 10 to 27

DB – 14 to 21

WB –15 to 15.5

Regarding places for installation

• Is the air conditioner installed at a well-ventilated 

place where there are no obstacles around?

• Do not use the air conditioner in the following 

places.

a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach area
c. Where sulfured gas exists such as a hot-spring 

resort

d. Where there are considerable voltage fluctua-

tions such as a factory or plant

e. Vehicles and vessels
 f. Where there is much spray of oil and vapor 

such as a cookery, etc.

g. Where there are machines generating electro-

magnetic waves

h. Filled with acid and/or alkaline steam or vapor

• Is a snow protection measure taken?

For details, consult your local dealer about snow 
protection hoods, etc.

Regarding wiring

• All wiring must be performed by an qualified 

personnel.

To do wiring, ask your local dealer. Never do it by 
yourself.

• Make sure that a separate power supply circuit 

is provided for this air conditioner and that all 
electrical work is carried out by qualified per-
sonnel according to local laws and regulations.

Pay attention to running noises, too

• Are the following places selected?

a. A place that can sufficiently withstand the mass 

of the air conditioner with less running noises 
and vibrations.

b. A place where the hot wind discharged from the 

air outlet of the outdoor unit and the running 
noises do not cause a nuisance to neighbours.

• Are you sure that there are no obstacles near 

the air outlet of the outdoor unit?

Such obstacles may result in declined perfor-
mance and increased running noises.

• If abnormal noises occur in use, stop the 

operation of the air conditioner, consult your 
local dealer.

Regarding drainage of drain piping

• Is the drain piping carried out properly to 

ensure complete drainage?

If drain piping is not carried out properly, dirt and 
debris may be accumulated in the drain piping 
and cause water leakage. If it occurs, stop the air 
conditioner and consult with your local dealer for 
assistance.

4. INSTALLATION SITE

01_EN_3P303408-2N.fm  Page 5  Thursday, February 20, 2014  3:49 PM

Summary of Contents for FHQ35CAVEB

Page 1: ...ded type SPLIT SYSTEM VRV SYSTEM FHQ35CAVEB FXHQ32AVEB FHQ50CAVEB FXHQ63AVEB FHQ60CAVEB FXHQ100AVEB FHQ71CAVEB FHQ100CAVEB FHQ125CAVEB FHQ140CAVEB FHQ140CAVEA English Deutsch Fran ais Espa ol Italiano...

Page 2: ...interior consulte tambi n los manu ales de instrucciones suministrados con la unidad exterior y el mando a distancia Vi ringraziamo per aver acquistato questo prodotto Per garantire un corretto funzi...

Page 3: ...es debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalaciones especiali zadas para su re...

Page 4: ...es a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or modera...

Page 5: ...e amount of any leaked refrigerant does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion CAUTION Children should be watched s...

Page 6: ...the control box fan motor drain pump etc make sure to shut off all power sup ply for the air conditioner including both indoor and outdoor units When cleaning the heat exchanger make sure to remove th...

Page 7: ...remote controller con trols one indoor unit system Confirm the following if your unit is of the following control system type Group control system One remote controller controls up to 16 indoor units...

Page 8: ...ch mineral oil such as cutting oil b Where there is much salt such as a beach area c Where sulfured gas exists such as a hot spring resort d Where there are considerable voltage fluctua tions such as...

Page 9: ...nerally takes a longer time for indoor temper ature of the HEATING OPERATION to reach the set temperature compared to the COOLING OPERATION It is advisable to start operation in advance using the TIME...

Page 10: ...the PROGRAM DRY OPERATION When the indoor temperature is lowered airflow from the air condi tioner may stop When operating continuously at downward airflow direction air blows in the automatically se...

Page 11: ...n Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle them Working while the blade is mov...

Page 12: ...ut your fingers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured 8 MAINTENANCE FOR SERVICE PERSONNEL CAUTION Do not wash the air cond...

Page 13: ...r After the air filter is cleaned return the air filter to the original place as it was attached before 5 Close the suction grille Slide all the knobs in the reverse order men tioned in the Clause 1 a...

Page 14: ...ped off dip the cloth in the neutral detergent diluted with water and twist the cloth After wiping off stain with this cloth wipe them with dry cloth NOTE Do not use such as gasoline benzine thinner p...

Page 15: ...the power is supplied to the air conditioner Some models perform the following operation to protect the devices If the HEATING OPERATION is performed within 6 hours after the power is supplied to the...

Page 16: ...n speed changes Raise the set temperature After a while the fan speed changes IV THE AIRFLOW DIRECTION IS DIFFERENT FROM THE SETTING OR THE AIRFLOW DIRECTION IS DIFFERENT FROM THE DIS PLAY ON THE REMO...

Page 17: ...st absorbed by the unit blows out IX THE INDOOR UNITS GIVE OFF ODORS During operation The unit absorbs the smell of rooms furni ture cigarettes etc and then emits them If odor is a concern you can set...

Page 18: ...and discharge direction Check if the airflow direction is not proper Set to an appropriate temperature fan speed and discharge direction Check if the doors or the windows are open Shut doors or windo...

Page 19: ...1D Measure Notify your local dealer and inform malfunction code of the display 10 2 FXHQ Read the operation manual attached to the out door unit UNIT No C L H OPERATION lamp INSPECTION display MALFUNC...

Page 20: ...3P303408 2N EM12A007B 1404 HT 00_CV_3P303408 2N_01 fm Page 2 Monday February 17 2014 9 23 AM...

Reviews: