background image

English

12

HEATING OPERATION within 6 hours after the 
power is supplied to the air conditioner.

Some models perform the following operation to 
protect the devices.
If the HEATING OPERATION is performed within 
6 hours after the power is supplied to the air con-
ditioner, the indoor fan stops for about 10 minutes 
during the outdoor unit operation to protect the 
devices.
The above operation is performed not only at the 
time of installation, but every time the power cir-
cuit breaker is turned off/on.
For comfortable use, do not turn off the power cir-
cuit breaker during seasonal use of the HEATING 
OPERATION.

WHAT TO DO TO STOP THE AIR CONDI-
TIONER FOR A LONG PERIOD

Turn on FAN OPERATION for a half day on the 
fine day and dry the indoor unit.

This can prevent the causes of mould.

Turn off the power circuit breaker.

During the power circuit breaker is turned on, 
some watts of electricity is being used even if the 
air conditioner is not operating.
Turn off the power circuit breaker for saving 
energy.

The display on the remote controller will vanish 
when the power circuit breaker is turned off.

Clean the air filter and outside panel

Be sure to replace the air filter to its original place 
after cleaning. (Refer to “

8. MAINTENANCE

” on 

page 9.)
For information on how to install, remove, or clean 
an optional sold air filter, refer to the user’s manual 
attached to the air filter.

NOTE 

The inside of the air conditioner may become con-
taminated after several seasons of use, potentially 
causing performance degradation and water leak-
age.
Ask your local dealer for details on cleaning the 
inside of the indoor unit. This operation requires a 
qualified service person.

9-1. FHQ

The following symptoms do not indicate air con-
ditioner malfunction

HEATING OPERATION within 6 hours after the 
power is supplied to the air conditioner.
Some models perform the following operation to 
protect the devices.
If the HEATING OPERATION is performed within 6 
hours after the power is supplied to the air condi-
tioner, the indoor fan stops for about 10 minutes dur-
ing the outdoor unit operation to protect the devices.
The above operation is performed not only at the 
time of installation, but every time the power cir-
cuit breaker is turned off/on.
For comfort heating, it is recommended not to turn 
off the power circuit breaker during the HEATING 
OPERATION.

I. THE AIR CONDITIONER DOES NOT OPERATE

• The air conditioner does not restart imme-

diately after the ON/OFF button is pressed.

• The air conditioner does not restart 

immediately when TEMPERATURE SET-
TING button is returned to the former 
position after pushing the button.

If the OPERATION lamp lights, the air condi-
tioner is in normal condition.
It does not restart immediately because a 
safety device operates to prevent overload of 
the air conditioner.
After approx. 3 minutes, the air conditioner 
will turn on again automatically.

• The air conditioner does not start when 

the display shows “

” and it 

flashes for few seconds after pressing an 
operation button.

This is because the air conditioner is under 
centralized control.
Flashes on the display indicates that the air 
conditioner cannot be controlled by the 
remote controller.

• HEATING OPERATION within 6 hours 

after the power is supplied to the air con-
ditioner.

Some models perform the following opera-
tion to protect the devices.
If the HEATING OPERATION is performed 
within 6 hours after the power is supplied to 
the air conditioner, the indoor fan stops for 
about 10 minutes during the outdoor unit 
operation to protect the devices.
The above operation is performed not only at 
the time of installation, but every time the 
power circuit breaker is turned off/on.

9. NOT MALFUNCTION OF THE 

AIR CONDITIONER

01_EN_3P303408-2N.fm  Page 12  Thursday, February 20, 2014  3:49 PM

Summary of Contents for FHQ35CAVEB

Page 1: ...ded type SPLIT SYSTEM VRV SYSTEM FHQ35CAVEB FXHQ32AVEB FHQ50CAVEB FXHQ63AVEB FHQ60CAVEB FXHQ100AVEB FHQ71CAVEB FHQ100CAVEB FHQ125CAVEB FHQ140CAVEB FHQ140CAVEA English Deutsch Fran ais Espa ol Italiano...

Page 2: ...interior consulte tambi n los manu ales de instrucciones suministrados con la unidad exterior y el mando a distancia Vi ringraziamo per aver acquistato questo prodotto Per garantire un corretto funzi...

Page 3: ...es debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalaciones especiali zadas para su re...

Page 4: ...es a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or modera...

Page 5: ...e amount of any leaked refrigerant does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion CAUTION Children should be watched s...

Page 6: ...the control box fan motor drain pump etc make sure to shut off all power sup ply for the air conditioner including both indoor and outdoor units When cleaning the heat exchanger make sure to remove th...

Page 7: ...remote controller con trols one indoor unit system Confirm the following if your unit is of the following control system type Group control system One remote controller controls up to 16 indoor units...

Page 8: ...ch mineral oil such as cutting oil b Where there is much salt such as a beach area c Where sulfured gas exists such as a hot spring resort d Where there are considerable voltage fluctua tions such as...

Page 9: ...nerally takes a longer time for indoor temper ature of the HEATING OPERATION to reach the set temperature compared to the COOLING OPERATION It is advisable to start operation in advance using the TIME...

Page 10: ...the PROGRAM DRY OPERATION When the indoor temperature is lowered airflow from the air condi tioner may stop When operating continuously at downward airflow direction air blows in the automatically se...

Page 11: ...n Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle them Working while the blade is mov...

Page 12: ...ut your fingers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured 8 MAINTENANCE FOR SERVICE PERSONNEL CAUTION Do not wash the air cond...

Page 13: ...r After the air filter is cleaned return the air filter to the original place as it was attached before 5 Close the suction grille Slide all the knobs in the reverse order men tioned in the Clause 1 a...

Page 14: ...ped off dip the cloth in the neutral detergent diluted with water and twist the cloth After wiping off stain with this cloth wipe them with dry cloth NOTE Do not use such as gasoline benzine thinner p...

Page 15: ...the power is supplied to the air conditioner Some models perform the following operation to protect the devices If the HEATING OPERATION is performed within 6 hours after the power is supplied to the...

Page 16: ...n speed changes Raise the set temperature After a while the fan speed changes IV THE AIRFLOW DIRECTION IS DIFFERENT FROM THE SETTING OR THE AIRFLOW DIRECTION IS DIFFERENT FROM THE DIS PLAY ON THE REMO...

Page 17: ...st absorbed by the unit blows out IX THE INDOOR UNITS GIVE OFF ODORS During operation The unit absorbs the smell of rooms furni ture cigarettes etc and then emits them If odor is a concern you can set...