• When the air conditioner is changed over 

to the HEATING OPERATION after the 
DEFROST OPERATION and in the 
DEFROST OPERATION.

Moisture generated by defrost becomes 
steam and will float around.
When the remote controller display shows 

”, DEFROST OPERATION is being 

used.

VII. NOISE OF AIR CONDITIONERS

• A ringing sound after the indoor unit 

starts.

This sound is generated when the motors for 
driving the horizontal blades are working.
It will quiet down after about a minute.

• A low continuous flow “Shuh” sound 

which is heard when the air conditioner is 
in the COOLING or DEFROST OPERA-
TION or a trickling sound which is heard 
when the air conditioner is in the 
DEFROST OPERATION.

This is the sound of refrigerant gas flowing 
through both indoor and outdoor units.

• A “Shuh” sound which is heard at the 

start or immediately after the stop of 
operation or which is heard at the start or 
immediately after the stop of the 
DEFROST OPERATION.

This is the noise of refrigerant caused by flow 
stop and flow change.
During the HEATING OPERATION, the air 
conditioner switches to the DEFROST 
OPERATION automatically.
The remote controller shows “

”.

After maximum 10 minutes, the air condi-
tioner returns to its original operation.

• A “Pishi-pishi” squeaking sound is heard 

when the air conditioner is in operation or 
after the stop of operation.

Expansion and contraction of resin parts 
caused by temperature change makes this 
noise.

VIII. DUST FROM THE INDOOR UNITS

• Dust may blow out from the unit after 

starting operation from long resting time.

Dust absorbed by the unit blows out.

IX. THE INDOOR UNITS GIVE OFF ODORS

• During operation

The unit absorbs the smell of rooms, furni-
ture, cigarettes, etc., and then emits them.
If odor is a concern, you can set to zero fan 
speed when the indoor temperature reaches 
the set temperature.
For details, contact your local dealer.

X. THE AIR CONDITIONER DOES NOT COOL 

EFFECTIVELY

• The air conditioner is operating in the 

PROGRAM DRY OPERATION.

This is because program dry mode operates 
so that the indoor temperature decreases as 
little as possible.
Lower the indoor temperature using the 
COOLING OPERATION, and then use the 
PROGRAM DRY OPERATION.
(Refer to “

CHARACTERISTICS OF THE 

PROGRAM DRY OPERATION

” on page 7.)

• Read through characteristics of the 

COOLING OPERATION, characteristics of 
the HEATING OPERATION, and character-
istics of the PROGRAM DRY OPERATION 
on page 6-7.

9-2. FXHQ

Read the operation manual that attached to the 
outdoor unit.

10-1. FHQ

Please check before requesting a service.

1. If the air conditioner does not operate at all.

Check if fuse has blown.
Turn off the power supply.

Check if the power circuit breaker is blown.
If the tab of power circuit breaker is in the OFF 
position, turn the power on with the power cir-
cuit breaker switch.
If the tab of power circuit breaker is in the trip 
position do not turn the power on with the 
power circuit breaker switch.
Contact your local dealer.

Check if there is a power failure.
Wait until power is restored. If power failure 
occurs during operation, the air conditioner 
automatically restarts immediately after the 
power supply recovers.

10. TROUBLE SHOOTING

Tab

Trip position

Power circuit breaker
(Earth leakage breaker)

ON

OFF

01_EN_3P303408-2N.fm  Page 14  Thursday, February 20, 2014  3:49 PM

Summary of Contents for FHQ35CAVEB

Page 1: ...ded type SPLIT SYSTEM VRV SYSTEM FHQ35CAVEB FXHQ32AVEB FHQ50CAVEB FXHQ63AVEB FHQ60CAVEB FXHQ100AVEB FHQ71CAVEB FHQ100CAVEB FHQ125CAVEB FHQ140CAVEB FHQ140CAVEA English Deutsch Fran ais Espa ol Italiano...

Page 2: ...interior consulte tambi n los manu ales de instrucciones suministrados con la unidad exterior y el mando a distancia Vi ringraziamo per aver acquistato questo prodotto Per garantire un corretto funzi...

Page 3: ...es debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalaciones especiali zadas para su re...

Page 4: ...es a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or modera...

Page 5: ...e amount of any leaked refrigerant does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion CAUTION Children should be watched s...

Page 6: ...the control box fan motor drain pump etc make sure to shut off all power sup ply for the air conditioner including both indoor and outdoor units When cleaning the heat exchanger make sure to remove th...

Page 7: ...remote controller con trols one indoor unit system Confirm the following if your unit is of the following control system type Group control system One remote controller controls up to 16 indoor units...

Page 8: ...ch mineral oil such as cutting oil b Where there is much salt such as a beach area c Where sulfured gas exists such as a hot spring resort d Where there are considerable voltage fluctua tions such as...

Page 9: ...nerally takes a longer time for indoor temper ature of the HEATING OPERATION to reach the set temperature compared to the COOLING OPERATION It is advisable to start operation in advance using the TIME...

Page 10: ...the PROGRAM DRY OPERATION When the indoor temperature is lowered airflow from the air condi tioner may stop When operating continuously at downward airflow direction air blows in the automatically se...

Page 11: ...n Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle them Working while the blade is mov...

Page 12: ...ut your fingers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured 8 MAINTENANCE FOR SERVICE PERSONNEL CAUTION Do not wash the air cond...

Page 13: ...r After the air filter is cleaned return the air filter to the original place as it was attached before 5 Close the suction grille Slide all the knobs in the reverse order men tioned in the Clause 1 a...

Page 14: ...ped off dip the cloth in the neutral detergent diluted with water and twist the cloth After wiping off stain with this cloth wipe them with dry cloth NOTE Do not use such as gasoline benzine thinner p...

Page 15: ...the power is supplied to the air conditioner Some models perform the following operation to protect the devices If the HEATING OPERATION is performed within 6 hours after the power is supplied to the...

Page 16: ...n speed changes Raise the set temperature After a while the fan speed changes IV THE AIRFLOW DIRECTION IS DIFFERENT FROM THE SETTING OR THE AIRFLOW DIRECTION IS DIFFERENT FROM THE DIS PLAY ON THE REMO...

Page 17: ...st absorbed by the unit blows out IX THE INDOOR UNITS GIVE OFF ODORS During operation The unit absorbs the smell of rooms furni ture cigarettes etc and then emits them If odor is a concern you can set...

Page 18: ...and discharge direction Check if the airflow direction is not proper Set to an appropriate temperature fan speed and discharge direction Check if the doors or the windows are open Shut doors or windo...

Page 19: ...1D Measure Notify your local dealer and inform malfunction code of the display 10 2 FXHQ Read the operation manual attached to the out door unit UNIT No C L H OPERATION lamp INSPECTION display MALFUNC...

Page 20: ...3P303408 2N EM12A007B 1404 HT 00_CV_3P303408 2N_01 fm Page 2 Monday February 17 2014 9 23 AM...

Reviews: