![background image](http://html1.mh-extra.com/html/daikin/rxta30b2v1b/rxta30b2v1b_service-manual_4215663162.webp)
4
|
Components
Service manual
162
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
4
Install the air filter, mount the front panel and close it.
FTXTP-M and ATXTP-M units
1
Install the front grille and firmly engage the 3 upper hooks.
2
Install 2 screws (class 20~35) or 3 screws (class 50~71) back on the front grille.
3
Install 2 screws back on the front grille.
4
Install the air filter and then mount the front panel.
To re-install the front panel
FTXTA-B units
1
Attach the front panel.
2
Align the shaft on right side with the shaft slot and insert it all the way in.
3
Push lightly the front panel to the right side, align the shaft on the left side
with slot and insert it all the way in.
4
Close the locks on both sides.
FTXTM-R, FTXTP-M and ATXTP-M units
1
Attach the front panel. Align the shafts with the slots and push them all the
way in.
2
Close the front panel, see
To install the switch box
FTXTA-B units
1
install the switch box in the correct location on the indoor unit.
b
a
c
d
e
f
a
Grouding wire cover screw
b
Grounding wire screw
c
Heat exchanger thermistor
d
Indoor unit PCB
e
Switch box screw
f
Switch box
2
Route the connectors of the indoor unit fan motor and front wiring inside the
switch box and connect them to the indoor unit PCB.
3
Install and tighten the screw to secure the switch box.
4
Install the heat exchanger thermistor in its holder.