4
|
Components
Service manual
158
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
a
b
a
Service cover screw
b
Service cover
NOTICE
When closing the service cover, make sure that the tightening torque does NOT
exceed 1.4 (±0.2) N•m.
TO REMOVE THE ELECTRICAL WIRING BOX COVER
Prerequisite:
Remove the front grille.
1
Remove 1 screw from the electrical wiring box.
2
Open the electrical wiring box cover by pulling the protruding part on the top
of the cover.
3
Unhook the tab(s) on the bottom and remove the electrical wiring box cover.
a
a
c
b
a
1
3
2
a
Tab
b
Protruding part on the top of the cover
c
Screw
b
a
c
c