4
|
Components
Service manual
193
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
11
Connect the drain hose to the indoor unit.
a
b
a
Screw (drain hose)
b
Drain hose
12
Install the drain hose fixation bracket. Install and tighten the screw.
13
Install the switch box, see
Is the problem solved?
Action
Yes
No further actions required.
No
Return to the troubleshooting of the
specific error and continue with the
next procedure.
FTXTM40R
1
Connect the wiring harness to the swing raster motor.
2
Install the gear on the swing raster motor shaft.
3
Install the swing raster motor (and gear) on the correct location on the
bracket.
a
c
a
b
a
Screw (swing raster motor fixation)
b
Swing raster motor
c
Gear
4
Guide the rod inside the bracket to the correct location. Make sure that the
teeth of the rod are properly fitted on the gear.