4
|
Components
Service manual
176
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
To install the swing flap motor
FTXTM30R
1
Install the coupling piece on the swing flap motor.
2
Install the swing flap motor in the correct location on the indoor unit.
b
a
c
d
a
Swing flap
b
Screw (swing flap motor fixation)
c
Swing flap motor
d
Coupling piece
3
Install and tighten the screw to fix the swing flap motor.
4
Install the swing flap.
5
Install the swing raster motor, see
186].
6
144].
Is the problem solved?
Action
Yes
No further actions required.
No
Return to the troubleshooting of the
specific error and continue with the
next procedure.
FTXTM40R
1
Connect the wiring harness to the swing flap motor.
2
Install the swing flap motor on the correct location on the indoor unit. Make
sure the swing flap motor shaft is correctly inserted in the link.