![background image](http://html1.mh-extra.com/html/daikin/rxta30b2v1b/rxta30b2v1b_service-manual_4215663139.webp)
4
|
Components
Service manual
139
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
e
d
e
f
g
e
c
b
b
b
b
a
d
d
a
Opening in partition plate
b
DC fan motor harness
c
Switch box
d
Harness retainer
e
Screw
f
DC man motor assy
g
Fan motor bracket
4
Detach the DC fan motor harness from the switch box.
5
Guide the DC fan motor harness though the opening in the partition plate.
6
Slightly bend the harness retainers (at the back of the fan motor bracket) to
detach the DC fan motor harness.
7
Remove the 4 screws that fix the DC fan motor assembly.
8
Remove the DC fan motor assembly from the unit.
9
To install the DC fan motor assembly, see
To install the DC fan motor assembly
1
Install the DC fan motor assembly in the correct location.
2
Fix the DC fan motor assembly to the unit by tightening the screws.
Summary of Contents for RXTA30B2V1B
Page 262: ......
Page 263: ......
Page 264: ...ESIE21 12A 2022 02 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...