4
|
Components
Service manual
121
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+35M5V1B
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02
a
b
a
Control panel
b
Intelligent eye sensor PCB
2
Disconnect the connector from the intelligent eye sensor PCB.
3
Carefully click the complete intelligent eye sensor PCB out of the indoor unit.
4
To install the intelligent eye sensor PCB, see
120].
To install the intelligent eye sensor
1
Click the intelligent eye sensor PCB on the indoor unit.
a
b
a
Control panel
b
Intelligent eye sensor PCB
2
Connect the harness to the intelligent eye sensor PCB.
3
Install the control panel on the indoor unit.
Is the problem solved?
Action
Yes
No further actions required.
No
Return to the troubleshooting of the
specific error and continue with the
next procedure.
To remove the intelligent eye sensor wiring harness
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
Summary of Contents for RXTA30B2V1B