![Daikin LCBKQ3AV1 Service Manual Download Page 158](http://html.mh-extra.com/html/daikin/lcbkq3av1/lcbkq3av1_service-manual_501887158.webp)
Troubleshooting
SiBE811001EB
157
CONVENI-PACK
Check the contents of abnormalities and retries
Contents of retires and abnormalities are checked as follows.
<Contents of abnormalities and retries>
k
: ON
h
: OFF
l
: Blink
Reference
Code
Contents of Error
Confirmation 1
Confirmation 2
Main content
Details
H1P
H2P
H3P
H4P
H5P
H6P
H7P
H1P
H2P
H3P
H4P
H5P
H6P
H7P
E0
Defective protection device
l h k h h l l l k h h h h h
E1
Defective outdoor unit PCB
Defective of PCB
l k h h h h l
E2
Failure due to earth leakage
l k h h h l h
E3
Defective high pressure
HPS actuation
l k h h h l l
E4
Defective low pressure
Pe error
l k h h l h h
E5
INV. compressor lock
l k h h l h l
E7
Defective the outdoor unit fan
motors
l k h h l l l
E9
Defective the electronic
expansion valve coil
For main (Y1E)
l k h l h h l
For liquid injection (Y2E)
For intermediate INJ (INV.) (Y3E)
For intermediate INJ (NON1) (Y4E)
For intermediate INJ (NON2) (Y5E)
EC
Booster unit alarm
l k h l l h h
EE
Defective target evaporating
temperature setting
l k h l l l h
EH
Communication error (outdoor
units - Booster unit)
l k h l h l l
EJ
Defective refrigeration (Booster
unit alarm)
l k h l l h l
F3
Defective the discharge pipe
temperature
Td error
l h k h l h l l k h h h l l
F4
Wet operation from refrigeration
suction pipe
l k h h k h h
F5
Wet operation from injection pipe
l k h h k h k
H0
Defective 3 sensors
l h k h l h h l k h h h h h
H3
Defective high pressure switch
l k h h h l l
H4
Defective low pressure switch
l k h h l h h
H7
Defective the outdoor unit fan
motors
l k h h l l l
H9
Defective outdoor air thermistor
R1T (
∗
1)
l k h l h h l
∗
1: Either short circuit or open.
<Selection of retry or abnormality item>
<Display Confirmation 1>
<Display Confirmation 2>
Press the BS1 (MODE) button in
"Setting mode 1" switches to "Monitor
mode."
Press the BS2 (SET) button to indicate
confirmation 2 on the lamp display.
Press the BS3 (RETURN) button to
switch to the initial status of the
"Monitor mode."
∗
Press the MODE (BS1) button and
returns to "Setting mode 1".
Press the SET (BS2) button and
select a monitoring item No. 0, 14, 15,
16 to check the lamp display.
Press the BS3 (RETURN) button to
indicate confirmation 1 on the lamp
display.
First digit
Second digit
Display of error codes