156
MAINTENANCE SERVICE
OF ELECTRIC EQUIPMENT
During operation protect aggregates of an electric equipment
from hit on them of oil and fuel, and also water at washing of the en-
gine.
ATTENTION!
MAINTENANCE SERVICE OF THE ALTERNA-
TOR CARRY OUT ACCORDING TO RULES OF «OPERATION
MANUAL" OF A VEHICLE, ON WHICH THE POWER UNIT IS
INSTALLED, AND, IN CASE OF ABSENCE OF SUCH INSTRUC-
TIONS TO BE GUIDED BY THE PRESENT INSTRUCTION.
GENERATOR
Periodicity and amount of works of maintenance service of gen-
erators of various models have the differences. It is necessary to be
guided by rules of maintenance service for the appropriate models of
the generator installed on your power unit.
ATTENTION!
THE START-UP OF THE ENGINE IS FOR-
BIDDEN ON THE AUTOMOBILE WITH THE GENERATOR
“PLUS” WIRE DISCONNECTED. THIS WILL CAUSE AN OVER-
VOLTAGE ON THE GENERATOR, DANGEROUS TO SILICON
RECTIFIER UNIT.
AT LONG PARKING OF THE VEHICLE TURN OFF THE
GROUND SWITCH IN ORDER TO PREVENT THE DISCHARGE
OF STORAGE BATTERIES THROUGH THE GENERATOR FIELD
WINDING.
IN ORDER TO PREVENT FAILURE OF GENERATOR UNIT
IT IS FORBIDDEN:
•
DISCONNECTING THE WIRE FROM GENERATOR
POSITIVE TERMINAL AND SWITCHING OFF THE BAT-
TERY BY USING THE GROUND SWITCH WITH THE
GENERATOR RUNING;
•
CHECKING SERVICEABILITY OF GENERATOR UNIT
BY CLOSING OF PLUGS TO THE GROUND WITH JAM-
PERS, OR ONE TO THE OTHER.
WHEN MOUNTING THE STORAGE BATTERIES ON THE
VEHICLE AND CONNECTING THEM, STRICTLY OBSERVE
POLARITY ("+" TO THE CIRCUIT, "-" TO THE GROUND).
Summary of Contents for ???-238??
Page 18: ...18 Fig 4 Overall Dimensions of Power Units 238 2 238 238 2 238 18...
Page 20: ...20 Fig 6 Engine Longi tudinal Section...
Page 38: ...38...
Page 213: ...213...
Page 225: ...225...