SRV-63 series AC servo drives Detailed parameter description
-160-
P6.21
Turret number
Setting range
Default
Unit
Available mode
1~128
16
piece
P
This parameter is used to set turret number.
P6.21
Data size
16bit
Data format
DEC
Modbus address
2242, 2243
CANopen address
0x2615, 0x00
P6.22
Turret pulse number per
cycle
Setting range
Default
Unit
Available mode
2~(2
31
-1)
10000
reference unit P
This parameter is used to set turret pulse number per cycle.
P6.22
Data size
32bit
Data format
DEC
Modbus address
2244, 2245
CANopen address
0x2616, 0x00
P6.23
1
Starting point of turret
Setting range
Default
Unit
Available mode
-(2
31
-1)~(2
31
-1)
0
reference unit P
This parameter is used to set starting point of turret.
P6.23
1
Data size
32bit
Data format
DEC
Modbus address
2246, 2247
CANopen address
0x2617, 0x00
P6.30
1
Gantry synchronization
function switch
Setting range
Default
Unit
Available mode
0~1
0
-
P
This parameter is used to set the gantry synchronization switch.
Setting value
Function
[0]
Disabled
1
Enabled
P6.30
1
Data size
16bit
Data format
DEC
Modbus address
2260, 2261
CANopen address
0x261E, 0x00
P6.31
Gantry synchronous
speed control gain
Setting range
Default
Unit
Available mode
0.0~3276.7
0.0
Hz
P
This parameter is used to set the gantry synchronous speed control gain.
P6.31
Data size
16bit
Data format
DEC
Modbus address
2262, 2263
CANopen address
0x261F, 0x00
P6.32
Gantry synchronous
speed control integral
Setting range
Default
Unit
Available mode
0.1~1000.0
1000.0
ms
P
This parameter is used to set the time constant of gantry synchronous speed control integral.
Please note that when this parameter is set to 1000, it means integral action is invalid.
P6.32
Data size
16bit
Data format
DEC
Modbus address
2264, 2265
CANopen address
0x2620, 0x00