SRV-63 series AC servo drives Detailed parameter description
-126-
Setting value
Function
0
Emergency stop switch is normal
[1]
Emergency stop switch is disabled
If the digital input set as EMG is active, then Er10-4 will occur.
Note:
1. If Er10-4 occurs, the servo drive will stop at the stopping mode set by P4.30.
2. Clearance of Er10-4: Please ensure there is no danger, and then clear the alarm signal
(disable the digital input configured as EMG). After clearing the alarm displayed, it is necessary to
enable the servo drive again to operate the servo system.
P3.41
1
Data size
16bit
Data format
DEC
Modbus address
1682,1683
CANopen address
0x2329,0x00
P3.43
1
Digital input filter
Setting range
Default
Unit
Available mode
1~800
1
0.125ms
P
S
T
F
This parameter is used to set the filter time of the digital input.
Note:
The parameter works alone for 10 digital inputs.
P3.43
1
Data size
16bit
Data format
DEC
Modbus address
1686,1687
CANopen address
0x232B,0x00
P3.44
Command pulse input
invalid setting disabled
Setting range
Default
Unit
Available mode
0~1
0
-
P
F
This parameter can set whether the digital input configured as command pulse disabling (0x008
or x0108) among P3.00~P3.09 is valid or not. If command pulse disabling function needs to be
blocked, this parameter will do the trick.
0:Valid; 1:Invalid
P3.44
Data size
16bit
Data format
DEC
Modbus address
1688,1689
CANopen address
0x232C,0x00
P3.45
1
Clearing mode of retention
pulse
Setting range
Default
Unit
Available mode
0~1
1
-
P
F
This parameter is used to set valid mode of the digital input configured as RPC (0x007 or 0x107)
among P3.00~P3.09.
Setting value
Function
0
ON level clear
[1]
Rising edge clear
P3.45
1
Data size
16bit
Data format
DEC
Modbus address
1690,1691
CANopen address
0x232D,0x00
P3.50
Range of position
arrival
Setting range
Default
Unit
Available mode
0~2
18
100
reference unit
P
F
This parameter is used to set the range of position arrival. When the deviation between the